Cover dimension
C-BIND SYSTEM
AA 5 mm
10 mm
cessories enabling binding and de-binding of covers of the C-BIND system.
B 13 mm
2 binding inserts /A1 and B1/ in O.CB Inserts for Atlas 300/MB 300/MBE 300
C 16 mm
not included as standard) - (dig 1)
de-binding wedge (dig 2) with AA jig (dig 3) in O.CB Debinding tool for Atlas 300/MB 300/MBE 300
D 20 mm
not included as standard)
E 24 mm
F 28 mm
Dig 1
G 32 mm
1. Choose the proper size of a cover
A1
by using the table (see above) or the
channel width selecting tool (7).
2. The dcuments to be bound must have
B1
a minimum thickness of 1,8 mm without
the covers. If the documents are thinner,
you must put a O.Filling Sticky which you
can buy from OPUS, to increase the thickness of the documents to be bound. For A,B,C sizes in
C-bind covers before binding you must fit both binding bars A1 & B1 in the binding slot. When
binding all other sizes of C-Bind covers, fit only B1 insert into the binding slot. Depend i ng
on amount of inserts used during binding, position of the extended back support (13) must be
changed. If in the binding slot there is only B1 Insert, the extended back support should be
moved forward, In the case of binding with two inserts A1 and B1 the extended back support (13)
should be move back.
3. When de-binding C-bind covers use the de-binding wedge which is available from OPUS.pl,
for Atlas 300 / MB 300 / MBE 300.
INPORTANT:
When using AA covers put the AA remove word de-binding jig on spine of the cover first.
4. Binding and de-binding covers from the C-bind system is done in a similar way to the
Metalbind system. In the C-Bind system you measure only the documents, not the documents
and covers. Use the cover selecting tool or the chart in this manual/user guide.
9
IMAGE PRESS DEVICE - SAFETY INSTRUCTIONS
Image Press device is available in OPUS offer.
• Before putting the machine into operation please read the Health & Safety precautions,
manufacturer recommendations and the operation manual.
• The operation manual should be easily available at any time for the operator.
• The equipment must not be placed near heating or ventilation units.
• The equipment should not be used in vicinity of inflammable liquids or gases.
• The equipment may be supplied electricity only through the original cord. A mains socket must
be provided with efficient earthing. The supply voltage must be consistent with the parameters
specified on the technical plate positioned on the equipment housing. Disobeying the above
rule may result in electric shock or fire.
• The power supply cable should be protected against any damage, and must not be used to pull
or remove the plug from the socket.
lever (2) and remove the document to-
gether with the wedge (5), then take the
OPUS Atlas 300 mono • User guide
wedge (5) out of the document carefully.
12. Make the planned changes to the docu-
ment. The cover and channel may be re-
Number of bound sheets
used (a maximum of three times).
15 - 40
41 - 90
91 - 120
121 - 145
146 - 185
186 - 230
231 - 265
Dig 2
dimension
266 - 300
2. The bound documentation must have thickness of at least 1,8 m
documentation is thinner, it is obligatory to use filling strips (
able at OPUS), to increase the thickness of bound documents. W
16 mm size and C sizes in C-BIND covers, put before binding bo
B1 to the binding slot and when using covers with size over 16
covers, put only one B1 insert into the binding slot.
3. When debinding C-BIND covers use debinding wedge included
Atlas 300/MB 300/MBE 300.
IMPORTANT! When using AA covers put AA jig on spine of the cov
4. Binding and de-binding of covers of the C-BIND system is perfo
with Metalbind system, but: measure the thickness of sheet pile to
cover selection tool and select appropriate cover.
8
• Before putting the machine into operation please read the safe
turer recommendations and the operation manual
• The operation manual should be easily available at any time fo
• The machine must not be placed near the heating units or vent
• The machine should not be used in vicinity of inflammable liqu
• The machine may be supplied only through the original cord.
provided with e cient earthing. The supply voltage must be c
meters specified on the technical plate positioned on the mac
the above rule may result in electric shock or fire
• The supplying cable should be protected against any damage,
the machine or to remove the plug from a socket
• Making any changes in the electric circuit or the supplying ca
• 2 binding inserts /A1 and B1/ in O.CB Inserts for Atlas 3
(not included as standard) - (dig 1)
• de-binding wedge (dig 2) with AA jig (dig 3) in O.CB Deb
(not included as standard)
Dig 1
A1
B1
B1
6
cover
number of
bound sheets
soft cover 15-40
AA
hard cover 20-40
A
41-95
B
96-125
C
126-150
D
151-190
E
191-230
F
231-265
G
266-300
IMAGE PRESS DEVICE - SAFETY INSTRUCTIONS
Image Press device is available in OPUS o er.
7
Dig 1
A1
Atlas 300 mono
Dig 3
EN