Engine - Barring With Starting System - MTU Detroit Diesel 12 V 2000 P62 Technical Publication

Table of Contents

Advertisement

90
6.1.2
Engine – Barring with starting system
Special tools
Designation / Use
Connector pliers
Unguarded rotating and moving engine components.
Risk of serious injury - danger to life!
DANGER
Engine – Barring with starting system
1. Disengage the bayonet ring-nut (4) of connector
X4 with connector pliers (2) and withdraw
connector (3) from ECU.
2. Bar engine in unloaded condition: Press START
button.
3. Let the crankshaft rotate until oil pressure is
indicated.
4. Engine start is automatically interrupted when
specified starting period is expired. If necessary,
re-start the engine after approx. 20 seconds.
5. Plug connector X4 (3) and use connector pliers
(2) to secure the bayonet ring (4) by turning it
clockwise until it latches into place.
MS15009/00E 06-09
• Before barring or starting the engine, ensure that nobody is in the danger zone.
• After working on the engine, check that all protective devices have been reinstalled
and all tools removed from the engine.
Task Description
Part No.
0135315483
Qty.
1
© MTU