MTU Detroit Diesel 12 V 2000 P62 Technical Publication page 92

Table of Contents

Advertisement

88
Fault
Alarm text
code
360
OPEN_LOAD CYL.
B10
361
POWER STAGE
FAIL 1
362
POWER STAGE
FAIL 2
363
STOP POWER
STAGE 1
364
STOP POWER
STAGE 2
365
STOP MV-WIRING
381
TRAN.OUT1
PLANT DEF
382
TRAN.OUT2
PLANT DEF
383
TRAN.OUT3
PLANT DEF
384
TRAN.OUT4
PLANT DEF
385
TRAN.OUT5
PLANT DEF
386
TRAN.OUT6
PLANT DEF
MS15009/00E 06-09
Meaning
Disconnection in wiring to
solenoid valve cylinder B10;
Misfiring
Defect in ECU (solenoid valve
power stage)
Defect in ECU (solenoid valve
power stage)
Solenoid valve or wiring or ECU
defective
automatic engine shutdown
Solenoid valve or wiring or ECU
defective
automatic engine shutdown
Solenoid-valve wiring faulty;
automatic engine shutdown
Binary transistor output plant 1
defective
Binary transistor output plant 2
defective
Binary transistor output plant 3
defective
Binary transistor output plant 4
defective
Binary transistor output plant 5
defective
Binary transistor output plant 6
defective
Task
1. Check wiring.
2. Contact Service.
Contact Service.
Contact Service.
1. Check wiring.
2. Try to re-start the engine (→ Page 51).
3. Contact Service.
1. Check wiring.
2. Try to re-start the engine (→ Page 51).
3. Contact Service.
1. Check wiring.
2. Try to re-start the engine (→ Page 51).
3. Contact Service.
Contact Service.
Contact Service.
Contact Service.
Contact Service.
Contact Service.
Contact Service.
Troubleshooting