Table Of Contents; Ada / Ansi / Ul; Product Safety Warnings - Assa Abloy Norton 5500 Series Installation Instructions Manual

Power operator push side
Hide thumbs Also See for Norton 5500 Series:
Table of Contents

Advertisement

Contents
ADA / ANSI / UL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Product Safety Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
PUSH (Stop) Side Mounting Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Adjustments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Input Power Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Final Electrical and Mechanical Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Inverter Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
PUSH (Stop) Side

ADA / ANSI / UL

1.
Americans With Disabilities Act (A.D.A.)
These door operators can be installed and adjusted to
conform with A .D .A .
2.
ANSI Standards
ANSI A117.1 - These door operators permit door
assemblies to conform to the requirements of this
specification "for buildings and facilities - providing
accessibility and usability for physically handicapped
people" .
ANSI A156.19 - These products are designed to conform to
this specification "for power assist and low energy power
operated doors" .

Product Safety Warnings

WARNING: To reduce risk of injury to person, use this operator only with Pedestrian Swing doors . FOR INDOOR USE ONLY
1.
READ AND FOLLOW ALL INSTRUCTIONS .
2.
Install only on a properly operating and balanced door .
A door that is operating improperly could cause severe
injury. Have qualified service personnel make repairs to any
hardware before installing the operator .
3.
Remove, or make inoperative, all locks (unless mechanically
and/or electrically interlocked to the power unit) that are
connected to the door before installing the operator .
4.
Do not connect the door operator to the source power
until instructed to do so .
5.
Never let children operate or play with door controls . Keep
2
Template . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
regulations .
Approved 2021-04-16
5500 Series Power Operator - PUSH SIDE Installation
- "PAS" Function is designed to meet or exceed all of
the requirements for the "Power Assist Door".
- "POR" Function is designed to meet or exceed
all of the requirements for the "Low Energy Power
Operated Door" .
3.
U.L. Listing
Underwriters Laboratories, Inc. listed for use on fire
and smoke barrier door assemblies when the 120VAC
(60Hz) power input is supplied through the normally
closed alarm contacts of a compatible UL Listed alarm
system or alarm panel .
remote control (when provided) away from children .
6.
Personnel should keep away from a moving door in
motion .
7.
Test door's features at least once a month . After
adjusting either force or limit of travel, retest
door operator's features . KEEP DOOR PROPERLY
OPERATING . An improperly operating door could
cause severe injury or death .
8.
Maximum door size: 48" (1219mm) wide x 250 lb
(113 .4kg)
9.
SAVE THESE INSTRUCTIONS .
Copyright © 2021, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9355-0007-020 Rev 1 03/21