B. Prepare door for arm assembly.
1 .
Using template on page 15, locate and
prepare two (2) 3/8" (9 .5mm) holes in
door for sex bolts . (Figure 4)
NOTE: Standard units are supplied
with sex nuts and bolts for 1-3/4"
(44mm) thick door. Sex nuts and
bolts for other door thicknesses are
available to order.
Install Operator
A. Remove cover from unit and set cover and screws aside.
B. Mount unit to frame. (Figure 5)
NOTE: Select Concealed or Surface option.
Concealed Wired Units Only:
Connect conduit to frame side of backplate .
Secure unit to frame with four (4)
1/4-20 x 1/2" machine screws or
#14-10 x 2-1/2" wood screws .
OR
Surface Wired Units Only:
Secure unit to frame with four (4)
1/4-20 x 1/2" machine screws or
#14-10 x 2-1/2" wood screws .
Mount conduit bracket (found in screw
pack) to unit backplate with four (4)
provided screws .
Connect wiring conduit to bracket .
6
5500 Series Power Operator - PUSH SIDE Installation
Figure 4
Copyright © 2021, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
Approved 2021-04-16
A
Ø3/8
L C Hinge or Pivot
(19)
Sex Nuts
(2x)
Left Hand Shown
Figure 5
1-1/16
1-3/4
(43)
(44)
Door Opening Angle
Up to 110°
12" (305mm)
111° to 170°
9-1/2" (241mm)
80-9355-0007-020 Rev 1 03/21