5500 Series Power Operator - PUSH SIDE Installation
PUSH Template
Left hand door opening to 110° shown .
Do not scale drawing.
Left hand door shown.
All dimensions given in inches (mm).
Frame reveal is 2-5/8"-6-3/4" (67mm-171mm) for this application.
Notes:
1 .
Thickness recommended for reinforcements in hollow metal
doors and frames is charted on page 4 .
2 .
This template information based upon use of 5" (127mm)
maximum width butt hinges or 3/4" (19mm) offset pivots . A
separate template is required for other conditions .
3 .
Conduit hole nearest hinge is suggested for 120 VAC power input .
4 .
Door must be visible by person operating activation switch(s) .
Switch(s) to comply with ANSI/BHMA standards .
Copyright © 2021, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or in
part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9355-0007-020 Rev 1 03/21
B
13-3/4
(349)
11-5/8
(295)
1-1/4
(32)
7/8
Ø 2X
(23)
A
3/8
Ø
(19)
Sex Nuts
(2x)
Approved 2021-04-16
13-1/16
(332)
7-5/8
(194)
3/4
(19)
1-1/16
(43)
1-3/4
(44)
Door Opening Angle
Up to 110°
111° to 170°
1/2
(13)
1/4-20 Machine Screw or
# 14-10 Wood Screw (4x)
Dim A
Dim B
12" (305mm)
15-3/4" (400mm)
9-1/2" (241mm)
13-1/4" (337mm)