M0092609-05
Table 12
-
Normal operation
Inducement Trigger
Above 19 percent
Inducement
None
Notification
None
World-Wide DEF Level Option 2
Initial indication
Level 1
Below 19 percent
Below 12.5 percent
None
None
Low-level lamp
Low-level lamp
illuminated
illuminated
Emission malfunction
lamp on solid
Selective Catalytic Reduction Warning System
Level 2
6 Percent reading
None
Low-level lamp
illuminated
Emission malfunction
lamp flashing
71
Operation Section
Level 3
0 Percent reading
The engine may be
derated by 50 percent
torque
A shutdown or low
idle only will be en-
forced after 5
minutes.
Low-level lamp
illuminated
Emission malfunction
lamp flashing
Stop lamp on solid