70
Operation Section
Selective Catalytic Reduction Warning System
(Table 10, contd)
Inducement Time
None
First Occurrence
The system must be fault free for 40 hours before the system will reset to zero. If the fault is intermittent, and returns within the 40 hours, then
the repeat inducement time will be triggered.
The override can only be used once.
Inducement Time
None
Repeat Occurrence
Inducement
None
Notification
None
Contact your Perkins dealer or your Perkins Distributor at level 1 warning, do not let the fault develop.
World-Wide DEF Level Warnings
Two options are available but only one option will be
enabled.
• The low-level warning lamp will operate when DEF
level reaches the trigger point of below 20 percent.
• At Level 1 the low-level warning lamp in the DEF
gauge will illuminate and the emission malfunction
lamp will be on solid.
• At Level 2 the low-level warning lamp for the DEF
is active and the emission malfunction lamp will
flash.
• At Level 3 all level 2 warning lamps are active,
plus the stop lamp will become active. The engine
will shut down or will only operate at 1000 RPM.
Filling the DEF tank will remove the warning from the
system.
Table 11
-
Normal operation
Inducement Trigger
Above 19 percent
Inducement
None
Notification
None
18 Hours
18 Hours
None
108 Minutes
None
None
Emission malfunction
Emission malfunction
lamp will be on solid
lamp will flash
World-Wide DEF Level Option 1
Initial indication
Level 1
Below 19 percent
Below 12.5 percent
None
None
Low-level lamp
Low-level lamp
illuminated
illuminated
Emission malfunction
lamp on solid
M0092609-05
50 Percent torque
Cycling the keyswitch
Shut down or idle
will give 20 minutes
Until fault heals
of full power
50 Percent torque
Cycling the keyswitch
Shut down or idle
will give 20 minutes
Until fault heals
of full power
Emission malfunction
Emission malfunction
lamp will flash
lamp will flash
The stop lamp will
activate
Level 2
Level 3
0 Percent reading
Empty tank
Engine may be de-
The engine may be
rated by 25 percent
derated by 50 percent
torque
torque.
A shutdown or low
idle only will be en-
forced after 5
minutes.
Low-level lamp
Low-level lamp
illuminated
illuminated
Emission malfunction
Emission malfunction
lamp flashing
lamp flashing
Stop lamp on solid

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

904j-e28t904j-e28ta