Perkins 904J-E36TA Operation And Maintenance Manual page 67

Industrial engines
Hide thumbs Also See for 904J-E36TA:
Table of Contents

Advertisement

M0092609-05
World-Wide Reduced Performance Setting
Table 5
-
Normal operation
Inducement Time
None
First Occurrence
The system must be fault free for 40 hours before the system will reset to zero. If the fault is intermittent, and returns within the 40 hours, then
the repeat occurrence inducement time will be triggered.
The override can only be used once
Inducement Time
None
Repeat Occurrence
Inducement
None
Notification
None
Contact your Perkins dealer or your Perkins Distributor at level 1 warning, do not let the fault develop.
Table 6
-
Normal operation
Inducement Time
None
First Occurrence
The system must be fault free for 40 hours before the system will reset to zero. If the fault is intermittent, and returns within the 40 hours, then
the repeat occurrence inducement time will be triggered.
The override can only be used once
Inducement Time
None
Repeat Occurrence
Inducement
None
Notification
None
Contact your Perkins dealer or your Perkins Distributor at level 1 warning, do not let the fault develop.
Table 7
Category 3 Fault (Non-Tampering NOx Control Monitoring and Impeded EGR)
-
Normal operation
World-Wide Reduced Performance Setting
Category 1 Fault (Tampering Dosing Interruption and Quality)
Level 1
2.5 Hours
5 minutes
None
Emission malfunction
lamp will be on solid
World-Wide Reduced Performance Setting
Category 2 Fault (Non-Tampering Dosing and Interruption)
Level 1
10 Hours
None
None
Emission malfunction
lamp will be on solid
World-Wide Reduced Performance Setting
Level 1
Selective Catalytic Reduction Warning System
Level 2
Level 3
70 minutes
50 Percent torque
Shut down or idle
Until fault heals
75 Percent torque
50 Percent torque
Shut down or idle
Until fault heals
None
Emission malfunction
Emission malfunction
lamp will flash
lamp will flash
The stop lamp will be
on solid
Level 2
Level 3
10 Hours
50 Percent torque
Shut down or idle
Until fault heals
2 Hours
50 Percent torque
Shut down or idle
Until fault heals
75 Percent of torque
Emission malfunction
Emission malfunction
lamp will flash
lamp will flash
The stop lamp will be
on solid
Level 2
Level 3
67
Operation Section
Override
Cycling the keyswitch
will give 20 minutes
of full power
Cycling the keyswitch
will give 20 minutes
of full power
Emission malfunction
lamp will flash
Override
Cycling the keyswitch
will give 20 minutes
of full power
Cycling the keyswitch
will give 20 minutes
of full power
Emission malfunction
lamp will flash
Override
(continued)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

904j-e28t904j-e28ta

Table of Contents