Fast Forward EnergyCam Getting Started Tutorial page 5

Hide thumbs Also See for EnergyCam:
Table of Contents

Advertisement

(2 sec) Run wM-Bus installation
The wM-Bus configuration is used and the device sends a default package. This can be used to
register the device at a collector prior to install it on a meter. The display shows the M-Bus ID and
the configured mode (T2 / S2). If the display shows "Cable", the used device isn't a RF device.
(3 sec) Install the device on a meter
To install the device - the button has to be pressed 3 seconds. Here shown INST-WB (Font White
on Black), V2.00, Build Number 11717.
(4 sec; PAUSE; 1 sec) Restart the device / Uninstall the device from a meter
To restart the device and prevent the device from trigger readings after removing it from a meter:
(5 sec) Info
The device shows the following info sequence. Every info is displayed for 2 seconds.
1
RF Mode and
Buildnumber
2
M-Bus ID
3
Serial Protocol
FAST_EnergyCam_Manual.docx | v1.30 | 8. December 2016
C
09965:
T2E09965
T2 09965:
T2E09965:
S2 09965:
S2E09965:
22048063 The M-Bus ID of the device.
MBUS
Modbus or M-Bus : see page 26
RF disabled, Build 9965
T2 Mode, Build 9965
T2 Mode - encrypted, Build 9965
S2 Mode, Build 9965
S2 Mode - encrypted, Build 9965
page 5 / 38