Product Specification - Kane KANE900 Plus Manual

Hand-held combustion analyser
Table of Contents

Advertisement

12.

PRODUCT SPECIFICATION

Parameter
Temp Measurement
Flue Temperature
Inlet Temperature
Gas Measurement
Oxygen
Carbon Monoxide
Carbon Monoxide, H
2
compensated
Nitric Oxide
(optional)
Nitrogen Dioxide
(optional)
Pressure (optional)
*2
Carbon Dioxide
*2
Losses
*2
Efficiency
*2
Excess Air
*2
Temp (Nett)
*2
CO/CO
ratio
2
*2
Poison Index
Pre-programmed Fuels
Dimensions
Weight
Handset
Probe
Ambient Operating Range
Power Supply (battery charger)
Battery Life
*1
Using dry gases at STP
*2
Calculated
KANE900 Plus Operators Manual
Resolution
Accuracy
1.0°C/F
+2.0°C +0.3% reading
0.1°C/F
+1°C +0.3% reading
*1
0.1%
+0.2%
3
1ppm,mg/m
+20ppm <400ppm
+5% >400ppm
3
1ppm,mg/m
+20ppm <400ppm
+5% <5000ppm
+10% >5000ppm
3
1ppm,mg/m
+5ppm <100ppm
+5% >100ppm
3
1ppm,mg/m
+5% full scale
0.1mbar
+5.0% full scale
0.1%
+0.3% reading
0.1%
+1.0% reading
0.1%
+1.0% reading
0.1%
+0.2%
1.0°C/F
+2°C +0.3% reading
0.0001
+0.0001
0.01%
+0.01
Natural gas, Town gas, Gascor, Light Oil, Heavy Oil,
Propane, Butane, Anthracite, Coke, Coal, Kinsale Gas.
1kg
220mm x 55mm x 120mm
L240mm x Dia8mm with 285mm long stainless steel shaft,
type K thermocouple and 1.5m long neoprene hose
+0°C to +40°C/10% to 90% RH non condensing
Input:
Output: 12 Vac off load
>8 hours from full charge
Range
0-600°C/32-1112°F
0-50°C/32-122°F
0-21%
*1
0-4000ppm, 0-5000mg/m
*1
0-10,000ppm, 0-12,000mg/m
*1
0-5000ppm, 0-6700mg/m
100ppm, 200mg/m
150 mbar
0-99.9%
0-99.9%
0-99.9%
0-2885.0%
0-600°C/32-1112°F
0-0.9999
0-99.99
110Vac/220 Vac nominal
3
3
3
3
Page 28