7.

STORING AND RETRIEVING DATA

The KANE900 Plus can store up to 100 combustion tests. Once stored, the data can
be viewed on the display or downloaded to a PC or printer.
7.1

Storing a 'Live' Test

While performing a test and viewing the data on the MAIN display access the STORE
menu as follows :-
Press
to access the STORE MENU
Mode:
Select from the following :-
Location:
Automaticaly allocates a location in the memory of the instrument for
the next test. On the display shown above the next location will be 3.
To store a test set MODE to STORE and press
be stored in the analysers memory.
Tip :
Make a note of the location number for your particular test as it may be
useful when downloading or printing.
7.2

Viewing and Printing a 'Stored' Test

Multiple tests can be printed easily with the KANE900 Plus.
Select PRINT under MODE in the STORE menu. This feature is in addition to the
VIEW/PRINT, STORE and DELETE options.
Press
to access the STORE
MENU
The cursor will move to the first number, use the
location and start printing.
Press
to move the cursor to the second number, select the last location to
print.
KANE900 Plus Operators Manual
MODE
LOCATION
PRESS 'STORE' TO LOG
STORE - Allows data to be stored in memory.
VIEW / PRINT - Stored data can be viewed or printed.
DELETE - Clears all data in memory.
MODE
LOCATION
STORE MENU
: STORE
:
3
. The current readings will
STORE MENU
: PRINT
: 1 TO 10
PRESS 'PRINT'
and
to select the
Page 22