2.3 Connection

2.3.1 Connecting the power cable and the grounding cable

The following shows how to connect the power cables and grounding cables.
CAUTION
Single phase
AC100V/200V
Primary side
Note 1)
Earth
leakage
breaker
(NV)
Secondry
L
side
PE terminal
Note 1) Always use the terminal cover for the earth leakage breaker.
Prepare the following items.
1)
Part name
Earth leakage breaker
Cable for primary power supply
Grounding cable
ACIN cable
2) Confirm that the primary power matches the specifications.
3) Confirm that the primary power is OFF and that the earth leakage breaker power switch is OFF.
4) Connect the ACIN cable to the breaker.
Connect the power terminals of the ACIN cable to the secondary side terminals of the earth leakage breaker. Also,
ground the FG terminal of the cable.
5) Connect the ACIN cable to the ACIN connector on the rear of the controller.
<1> Face the main key on the ACIN cable plug upwards. (Refer to the "ACIN cable connection" illustration.)
<2> Align the main key of the ACIN cable plug with the grooves on the ACIN connector. Push the plug into the connec -
tor as far as it will go.
The plug may be damaged if it is not correctly aligned with the connector.
<3> Tighten the coupling on the ACIN cable, turning it to the right until it locks.
6) Connect one end of the grounding cable to the PE (protective earth) terminal on the controller and ground the other end
(2-point grounding) in order to comply with the requirements of EN 61800-5-1 for the touch current of 3.5 mA AC or
more.
7) Connect the primary power cable to the primary side terminal of the earth leakage breaker.
Please install the earth leakage breaker in the primary side power supply of the
controller because of leakage protection.
Controller rear
ACIN cable
(attachment)
PE (protective earth) terminal
M4 screw
N
Grounding cable
PE terminal
Specifications
Recommended product: Single phase NV30FAU-2P-
10A-AC100-240V-30mA (manufactured by Mitsubishi
Electric).
Make sure to attach the TCS-05FA2 terminal cover
(manufactured by Mitsubishi Electric).
2
AWG14 (2mm
) or above
2
AWG14 (2mm
) or above
Terminal: M5, cable length: 3m
ACIN cable connection
<1> <2>
ACIN connector
<3>
Prepared by customer.
Recommended specifications:
・ Rated current: 10A
・ Rated sensed current: 30mA
・ Rated breaking capacity: 2.5kA
Prepared by customer.
Tightening torque for terminal
fixing screw is 2 ~ 3Nm.
Prepared by customer.
Tightening torque for terminal
fixing screw is 2 ~ 3Nm.
Supplied with the product.
Installation and connectionInstallation 2-8
2Unpacking to installation
Groove for main
key (wide)
Top
ACIN connector
(female)
Main key (wide)
Top
ACIN cable
(male)
Coupling
Remarks