Troubleshooting; Resolving Operating Errors; Error Codes - DeDietrich ESSENCIO CF 22 User Manual

Oil/gas-fired boiler
Table of Contents

Advertisement

8 Troubleshooting

8
Troubleshooting
8.1

Resolving operating errors

8.2

Error codes

Tab.44
List of error codes
Error code
Message
H00.00
TFlow Open
H00.01
TFlow Closed
H00.06
TReturn Missing
H00.16
DHW sensor Open
H00.17
DHW sensor Closed
H00.32
TOutside Open
H00.33
TOutside Closed
H00.79
TSwimming Pool Open
H00.80
TSwimmingPool Closed
H01.03
Flame Loss Warning
H02.00
Reset In Progress
H02.02
Wait Config Number
H02.03
Conf Error
H02.04
Parameter Error
H02.05
CSU CU mismatch
H02.09
Partial block
H02.10
Full Block
34
CFU
If the boiler malfunctions, a code is displayed on the main screen of the
control panel. This code is important for the correct and rapid diagnosis of
the type of malfunction and for any technical assistance that may be
needed.
There are 3 types of error:
Tab.43
Type of code
Error
Fault
Alarm
1. Make a note of the code displayed on the screen.
2. Remedy the problem described by the error code or contact the
installer.
3. Switch the boiler off and back on to check that the cause of the error
has been removed.
4. If the code is displayed again, contact the installer.
An error code is a temporary status resulting from the detection of an
anomaly on the boiler.
When one of the codes below is displayed, contact the professional
responsible for maintenance of the boiler.
Description
Flow temperature sensor is either removed or measures a temperature below
range
Flow temperature sensor is either shorted or measures a temperature above
range
Return temperature sensor was expected but not detected
Domestic Hot Water tank temperature sensor is either removed or measures a
temperature below range
Domestic Hot Water tank temperature sensor is either shorted or measures a
temperature above range
Outside temperature sensor is either removed or measures a temperature
below range
Outside temperature sensor is either shorted or measures a temperature
above range
Swimming Pool Flow temperature sensor is either removed or measures a
temperature below range
Swimming Pool Flow temperature sensor is either shorted or measures a
temperature above range
Warning off uninteded flame loss detection
Reset In Progress
Waiting For Configuration Number
Configuration Error
Parameter Error:
CSU does not match CU type
Partial blocking of the device recognized
Full blocking of the device recognized
Code format
Hxx.xx
Exx.xx
Axx.xx
7740500 - v02 - 12022021