Osd2254P Operation; Connections - Optical Systems Design OSD2254P Series Operator's Manual

6-port redundant ring gigabit ethernet switch with poe++ source
Table of Contents

Advertisement

2.3

OSD2254P OPERATION

When using the OSD2254P for the first time, check that the unit is in good condition with no visible
damage.
Upon power up check that the indicators illuminate accordingly on power up (see Table 4).
2.3.1

CONNECTIONS

For RJ45 connection use Category 5 (CAT5) or higher. Length should be no more than 100 meters.
For singlemode fiber connections, fiber used must be 9/125µm singlemode fiber.
For multimode fiber connections, fiber used must be 50/125µm or 62/125µm multimode fiber.
Plug in the appropriate connectors for system configuration;
RJ45 cable to fixed copper ports (port 1 and 2) and copper SFP modules
LC or SC fiber cable to fiber SFP modules.
Redundant Ring Operation
The OSD2254P connected in a redundant ring topology providing maximum reliability on critical
networks. In the event of device or fiber failure the data path will automatically switch to a secondary
path in less than 2ms per node to maintain ring network integrity.
FIGURE 13: REDUNDANT RING CONFIGURATION
PAGE 18
OPTICAL SYSTEMS DESIGN
OSD2254P OPERATOR MANUAL
DOC ID: 10115206

Advertisement

Table of Contents
loading