Siemens SIMATIC HMI Unified Comfort MTP700 Operating Instructions Manual page 157

Hide thumbs Also See for SIMATIC HMI Unified Comfort MTP700:
Table of Contents

Advertisement

Interfaces
RS 422/485
PROFINET (LAN)
USB 3.1
With integrated switch (one IP address only)
1
USB Type A; maximum load per interface: 900 mA; maximum total load of all interfaces: 1.2 A
2
Power supply
Rated voltage
Permitted voltage range
Mains and voltage buffering time
Rated current at 24 V DC, without loads
Rated current, load-dependent
Power consumption, without loads
Inrush current I
t
2
Maximum permitted transient
Minimum time between two transients
Internal protection
The power loss generally corresponds to the specified value for power consumption.
1
The current and power specifications apply without a high permanent processor load by apps.
Miscellaneous
Buffered real-time clock
Audio reproduction
Buffering time typically 6 weeks
1
Unified Comfort Panels
Operating Instructions, 03/2020, A5E46641217-AA
Unified Comfort HMI device
Unified Comfort HMI device
1
Unified Comfort HMI device
1
MTP700
MTP1000
1 x SUB-D
2 x RJ45 10/100 Mbps
1 x RJ45 10/100/1000 Mbps
4 x Host
MTP700
MTP1000
24 V DC
+19.2 V ... +28.8 V
0.45 A
0.45 ... 1.0 A
0.52 ... 1.1 A
10.8 W
12.5 W
0.5 A
35 V (500 ms)
MTP700
MTP1000
Integrated buzzer
Technical information
8.8 Technical specifications
MTP1200
1
2
MTP1200
20 ms
0.5 A
0.6 A
0.6 ... 1.3 A
14.4 W
s
2
50 s
Yes
MTP1200
Yes
157

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents