Operating the Control Panel
5.5 Network and Internet
IP address
● "Obtain an IP address via DHCP" (default setting): Option to automatically assign the IP
address via the DHCP server.
● "Specify an IP address": Option to manually assign the IP address.
● "IP address": IP address of X1 interface for the X1P1 and X1P2 ports. The IP address
must be unique in the local network. The IP addresses of X1 and X2 interfaces must be
located in different subnets.
● "Subnet mask": Subnet mask for the IP address of X1 interface.
● "Default gateway": IP address of the gateway (router) if several different local networks
are used.
● "Set IP address": Button for saving the specified IP address parameters.
Note
You can also configure the network address in the "Devices & Networks" editor in WinCC.
You can find more information in the TIA Portal information system.
Note
If you select the option "Specify an IP address via DHCP", this setting will not be overwritten
when the project is loaded. If you select the option "Specifiy an IP address", you can also
configure the network address in the "Devices & Networks" editor in WinCC. You can find
more information in the TIA Portal information system.