Replacing The Fan - IBC VX Series Installation & Operating Manual

Residential condensing boiler
Table of Contents

Advertisement

Fan plug
Combustion Fan
High Fire Adjustment
Gas valve support bracket
Venturi insert clip
Venturi insert
Figure 45
Gas valve and fan components

7.3.1 Replacing the fan

1. Turn off the electric power and gas supply to the boiler.
2. Ensure the boiler cools down to the surrounding temperature. Do not drain the boiler unless
freezing conditions are expected during this procedure.
3. Remove the front cover, and then remove the four Torx 20 head screws on the top panel of
the boiler.
A ladder or step may be required to have a clear vertical view of the work area. Do not
attempt to reach from the front without a clear view, as damage to connectors, screws or
refractory may occur.
4. Undo the union nut at the gas valve outlet.
5. Carefully remove the O-ring and orifice for re-installation later.
6. Remove the electrical connection
7. Move the gas valve outlet tube
8. To remove the fan, unscrew the two bolts at the base of the fan, and retain with the
washers and fan gasket.
9. Carefully lift and remove the fan from the boiler case.
10. From the fan, remove the venturi insert clip
valve outlet tube
11. From the fan inlet
12. Remove the fan gasket.
13. Position the fan gasket (supplied in kit) onto the new fan, so that the holes align.
14. Secure the new fan onto the heat exchanger lid with bolts and washers.
15. Ensure that the venturi insert is in place.
to the fan.
away from the gas valve.
. Retain for reassembly.
, remove the venturi insert
78
Section: Service and maintenance
(with a flathead screwdriver) and the gas
.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vx 110Vx 150Vx 199Ibgfsw1-0110Ibgfsw1-0150Ibgfsw1-0199