IBC VX Series Installation & Operating Manual page 87

Residential condensing boiler
Table of Contents

Advertisement

1.
Pull back the clip to release the trap, and
pull the trap downwards to remove.
7.5 Cleaning the condensate trap
Condensate traps should
be checked every year,
cleaned and refilled as
necessary. Before cleaning
the condensate trap, you
must turn off the power to
the boiler, and allow it to
cool down.
Important: Installers or
service contractors should
ensure that the end user is
instructed on cleaning and
refilling the trap.
2.
Unscrew the condensate union cap at
the base of the trap, empty the water
and flush the trap with water.