Technical Data For Hesomatic-9 Stud Welding System - Soyer HesoMatic-9 Operating Instructions Manual

Stud welding system
Table of Contents

Advertisement

6.6

Technical data for HesoMatic-9 stud welding system

Designation
Welding procedure
Standard gun
Welding area
Power source
Charging voltage
Welding sequence
Mains connection
Compressed-air supply
Fuse
Energy source
Fuse
Feeder control
Cooling method
Protection class
Dimensions
Weight
Filling weight (feeder
bowl)
Colour
Subject to technical changes
Hazards due to wrong fuse
Only replace fuses when mains plug is disconnected!
Should it become necessary to replace fuses, only use fuses with the specified
electrical values. Oversized fuses could either cause defects on the electrical system
or a fire.
26
Operating instructions HesoMatic-9 | Heinz Soyer Bolzenschweißtechnik
HesoMatic-9
Capacitor discharge stud welding
PS-3A
M3 - M8 or Ø 3 - 8 mm with steel, stainless steel, aluminium and
brass (M8 or Ø 8 in aluminium and brass limited, depending on the
respective requirements)
Capacitor bank 99,000 µF
50 - 200 V infinitely variable up/down
Ø 3 up to 24 studs/min, Ø 8 up to 7 studs/min
230 V, 50/60 Hz, 10 A
5 - 7 bar
M 10 A (fuse 5 x 20 mm semi time-lag)
2 x T 1 A (time-lag fuse 5 x 20 mm)
F
IP 21
430 x 310 x 690 mm (w x h x d) >> Height with holding device 1960 mm
90 kg (without welding gun)
max 6 kg
RAL 5009 azure blue