Framing Dimensions Corner Kit - Corner Install (Left Corner) - Regency City ACB60ENG Owners & Installation Manual

Direct vent
Table of Contents

Advertisement

Framing Dimensions Corner Kit - Corner Install (Left Corner)

NOTE: Framing may be constructed of combustible material and does not require steel studs.
Framing
Description
Dimensions
A
Framing Height
B*
Framing Width
C*
Framing Depth
D
Unit Base to Top Enclosure (Min.)
G
Vent Centerline Height
NOTE: Unit cannot be load-bearing. All finishing materials must be supported by the framing.
Note: This appliance must be in-
stalled on a level and solid surface
such as a plywood floor which must
be the full width and depth of the
appliance.
*
Max
4cm x 14 cm
Max 4cm x 14 cm
Corner Kit
1137 mm
1810 mm
516 mm
2038 mm
1478 mm
*
Note: Unit must be installed onto a solid back wall
- do not install directly onto studs.
*Note: The framing width (B) and framing depth (C)
does not take into account plasterboard/wood
or similar materials against the back wall. The
framing width/depth will need to change based
on the thickness of the material
Example B : 1810 mm framing width + 13 mm
plasterboard = 1823 mm.
Example C : 516 mm framing depth + 13 mm
plasterboard = 529 mm.
installation
Note: A combined minimum of
1161 square centimeters of open
area is required for the convection
air outlet to cool the enclosure.
Ensure clearances for Convection
Air Outlets are met.
See clearances ACB60E in this
manual as there are different meth-
ods as to how this can be achieved.
City Series ACB60E | 35

Advertisement

Table of Contents
loading

Table of Contents