terminal device. Ten operation time records are displayed for each T command entry. The operation
time log can be cleared ONLY by factory authorized personnel using the Clear Log option in the
Factory menu.
9.4.3

Sensor Log

The sensor values can be logged at a different rate if needed by setting the Sensor Log Interval in
the Diagnostics Menu. The log interval can vary from once every minute to once every day. Table 9-
3 shows a sample Sensor Log every 5 minutes for a boiler running in Constant Setpoint mode.
No.
0
1
2
Status
Off, Direct Drive
Run, Direct Drive
Run, Direct Drive
Run, Direct Drive
Run, Direct Drive
Ignition
Off, Switch
Run, Manual
Ignition
Power-up
Setpt
Outlet
Outdr
130
181
OPEN
130
180
OPEN
130
180
OPEN
130
179
OPEN
130
180
OPEN
130
180
OPEN
130
180
OPEN
130
180
OPEN
130
179
OPEN
130
180
OPEN
AERCO International, Inc. • 100 Oritani Dr. • Blauvelt, NY 10913 • Ph: 800-526-0288
PR2: 04/22/13
Benchmark 2.0LN Dual-Fuel Low NOx Boiler
Operation and Maintenance Manual
The Sensor (S) Log can store up to 1200 records. Therefore,
to view the most recently logged record, enter "S" followed by
0 (zero) and then press Enter (i.e. S0 <Enter>). To view
earlier records in reverse chronological order, enter S and
press Enter. To go back 200 or 700 records, enter S200 or
S700, etc. and press Enter.
Table 9-1. Sample Fault Log Display
Fault Message
Direct Drive Signal Fault
Low Gas Pressure
Loss of Power
Table 9-2. Sample Operation Time Log Display
Fire Rate
0
38
31
35
29
0
0
40
0
0
Table 9-3. Sample Sensor Log Display
FFWD
Aux
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
NOTE
Cycle
Date
609 1/10/02
366 7/04/01
0 1/01/01
Flame
Run Length
0
8
100
34
100
30
100
2
100
0
0
0
0
35
100
0
0
0
0
0
Inlet
Exhst
CO
OPEN
OPEN
0
OPEN
OPEN
0
OPEN
OPEN
0
OPEN
OPEN
0
OPEN
OPEN
0
OPEN
OPEN
0
OPEN
OPEN
0
OPEN
OPEN
0
OPEN
OPEN
0
OPEN
OPEN
0
CHAPTER 9: RS232 COMMUNICATION
Time
8:42am
5:29pm
11:50am
Date
Time
1/15/02
2:35pm
1/15/02
2:27pm
1/15/02
1:53am
1/15/02
1:23pm
1/15/02
1:21pm
1/15/02
1:20pm
1/15/02
12:30pm
1/15/02
11:55am
1/15/02
11:55am
1/15/02
11:50am
O2
Flow
Date
.0
0
1/15/02
.0
0
1/15/02
.0
0
1/15/02
.0
0
1/15/02
.0
0
1/15/02
.0
0
1/15/02
.0
0
1/15/02
.0
0
1/15/02
.0
0
1/15/02
.0
0
1/15/02
Page 101 of 158
Time
5:51pm
5:46pm
5:41pm
5:36pm
5:31pm
5:26pm
5:21pm
5:16pm
5:11pm
5:06pm