OCP
OVP
OPP
Voltage programming
Voltage monitoring
Current programming
Current monitoring
Voltage range
OVP
UVP
Frequency
Max. current (rms)
DC Offset
Working temperature
Storage temperature
Noise
Measurement range
Measurement accuracy
Measurement resolution
Max. efficiency (Full-
load)
Communication interfaces
Size and weight
Net weight
Load Mode:
External analog (optional)
AC parameters
Environment
External temperature measurement
Efficiency
Communication(Optional)
RS232/USB/RS485/CAN/LAN/GPIB/Analog
Mechanical parameters
Copyright © Itech Electronic Co., Ltd.
Technical Specification
-12.5A or 12.5A
155V
-210W or 210W
External 0V~10V is 0~150V
External 0V~10V is 0~150V
External -10V~10V is -12A~12A
External -10V~10V is -12A~12A
100VAC -240VAC
264VAC
90VAC
47Hz~63Hz
1Aac (AC220)
-0.1A~+0.1A
0- 40 °C
-20- 70℃
60dB
-20℃——120℃
±1℃
0.1℃
88%
450mm*214mm*43.5mm
5kg
150