Internal Resistance
(CV Priority mode)
CP
CR mode(CC Priority
mode)
Read-back current
Read-back Voltage
Read-back Power
Temperature
Coefficient
AH Measurement
Load Regulation
Line Regulation
Setup Resolution
Accuracy
Range
Setup Resolution
Accuracy
Range
Setup Resolution
Accuracy
Range
Resolution
Accuracy
Output Read-back
Range
Resolution
Accuracy
Range
Resolution
Accuracy
Range
Resolution
Accuracy
Temperature Coefficient
Voltage Temperature
Coefficient
Current Temperature
Coefficient
Battery Test
AH Range
Accuracy
Resolution
Regulation
Voltage
Current
Voltage
Current
Copyright © Itech Electronic Co., Ltd.
Rmin:(Vreal-Vmax*0.1%)/Rset -Imax*0.2%
Rmax:(Vreal+Vmax*0.1%)/Rset +Imax*0.2%
Ripple
Technical Specification
1mV
<0.1% Umax
0-1000mΩ
0.1mΩ
2%*Rmax
-400W~400W
0.1W
<1.0% Pmax
0.6-1000Ω
Min.0.1Ω
-30A~30A
1mA
≤0.1%+0.1%FS
0-60V
1mV
<0.1% Umax
-400W~400W
0.1W
<1% Pmax
100ppm/℃
50ppm/℃
0AH-300AH
0.20%
0.001AH
≤0.05% Umax
≤0.05% Imax
≤0.05% Umax
≤0.05% Imax
139