2. INSTALLATION

To assemble the OM13 into the EPI-2 actuator,
proceed as follows:
• Ensure that all the parts received with
the OM13 are available as described in
paragraph 4.
• Using paragraph 4, select only mechanical
parts (screws and spacers) depending on
actuator models.
• Gather the right tools for the assembly and
for setting the actuator controls.
• With an Allen wrench of 5 mm unscrew the
cover screws (Figure 1).
• Remove the actuator cover (Figure 2).
Follow one of the following assembling
procedures depending on actuator model.
2.1 Assembling procedure for models
63-125 Nm old version (US or NO US market)
• Verify that you received the correct OM13
3-wire module (Figure 3).
• Remove (as indicate in Figure 4):
- 3-pins connector cable
- 4-pins connector cable
- 8-pins connector cable
• Remove the 3-wire power connector cable
from the power card as indicated in Figure 5.
• Remove the 3 screws (3 pcs M3x10) from the
logic board and screw the 3 metal spacers
(Figure 6).
• Place the OM13 card onto the spacers and
tighten the 4 screws (Figure 7).
• Remove the 2-pins connector cable from J1
on the power card (Figure 8).