Download Print this page
Emerson KEYSTONE OM13 EPI-2 Installation And Maintenance Instructions Manual

Emerson KEYSTONE OM13 EPI-2 Installation And Maintenance Instructions Manual

Wires module
Hide thumbs Also See for KEYSTONE OM13 EPI-2:

Advertisement

KEYSTONE OM13 - EPI-2 3-WIRES MODULE
INSTALLATION AND MAINTENANCE INSTRUCTIONS
Before installation these instructions must be fully read and understood

TABLE OF CONTENTS

1
3-wires module ............................................ 1
2
Installation .................................................... 2
3
4
OM13 kit ........................................................ 9
5
OM13 wiring diagram ................................ 10
Emerson.com/FinalControl

1. OPTIONAL MODULE 13: 3-WIRES MODULE

1.1 OM13 module functionality
The OM13 3-wires module is supplied as an
option to the Keystone EPI-2 actuators.
It is possible to receive the actuator already
equipped with the OM13, ordering it with the
basic feature.
Alternatively, it is possible to order the OM13 as
a separate kit and install it in the basic actuator
in the factory or in the field.
The OM13 is an optional module suitable
to accomplish the following EPI-2 actuator
additional functionality:
• 120/240 V AC 1-phase, 50/60 Hz, 3-wire
control for open/close operations, without
additional power supply.
IMPORTANT
For decommissioning instructions, please refer
to the relevant chapter in the EPI-2 manual ref.
VCIOM-02819.
IMPORTANT
The OM13 command has to be provided by two
separate switches for open and for close with
a delay of at least one second between the two
commands, when reversing the operation from
open to close or vice versa.
WARNING
EPI-2 actuator must be electrically isolated before
any disassembling or reassembling operations.
Before any disassembling or reassembling
operations, please follow in detail the relevant
paragraph of the basic installation and operating
manual (latest revision available).
WARNING
The electronic parts of the EPI-2 actuators and all
optional modules can be damaged by a discharge
of static electricity. Before you start, touch a
grounded metal surface to discharge any static
electricity.
WARNING
It is assumed that the installation, configuration,
commissioning, maintenance and repair works
are carried out by qualified personnel and
checked by responsible specialists.
© 2017 Emerson. All Rights Reserved.
WARNING
Repair work, other than operations outlined in this
manual, is strictly reserved to qualified Emerson
personnel or authorized by the company itself.
1.2 Manufacturer
Manufacturer with respect to Machinery
Directive 98/37: as specified on the EPI-2 label.
VCIOM-01495-EN 15/05

Advertisement

loading

Summary of Contents for Emerson KEYSTONE OM13 EPI-2

  • Page 1: Table Of Contents

    Repair work, other than operations outlined in this 1.1 OM13 module functionality Optional module 13: manual, is strictly reserved to qualified Emerson 3-wires module ..........1 The OM13 3-wires module is supplied as an personnel or authorized by the company itself.
  • Page 2: Installation

    KEYSTONE OM13 - EPI-2 3-WIRES MODULE INSTALLATION AND MAINTENANCE INSTRUCTIONS 2. INSTALLATION To assemble the OM13 into the EPI-2 actuator, proceed as follows: • Ensure that all the parts received with the OM13 are available as described in paragraph 4. • Using paragraph 4, select only mechanical parts (screws and spacers) depending on actuator models.
  • Page 3 KEYSTONE OM13 - EPI-2 3-WIRES MODULE INSTALLATION AND MAINTENANCE INSTRUCTIONS • Connect the 2-wire power connector cable of the OM13 card to the power card (Figure 9). • Connect the 3-wire power connector cable of the terminal board to the OM13 card (Figure 10).
  • Page 4 KEYSTONE OM13 - EPI-2 3-WIRES MODULE INSTALLATION AND MAINTENANCE INSTRUCTIONS • Remove the 3-wire power connector cable from the power card (Figure 17). • Remove the 2-pins connector cable from J1A on the logic card (Figure 18). Figure 17 Figure 18 •...
  • Page 5 KEYSTONE OM13 - EPI-2 3-WIRES MODULE INSTALLATION AND MAINTENANCE INSTRUCTIONS • Connect the 2-pins connector black cable from the OM13 module to connector J1A on the logic card (Figure 25). Figure 25 Figure 26 2.3 Assembling procedure for models 63-125 Nm new version (US or NO US market) •...
  • Page 6 KEYSTONE OM13 - EPI-2 3-WIRES MODULE INSTALLATION AND MAINTENANCE INSTRUCTIONS • Reconnect the 8-pins connector cable and 4-pins connector black cable (Figure 33). • Connect the 3-wire power connector cable of the terminal board to the OM13 card (Figure 34). Figure 33 Figure 34 •...
  • Page 7 KEYSTONE OM13 - EPI-2 3-WIRES MODULE INSTALLATION AND MAINTENANCE INSTRUCTIONS • Remove the 3-wire power connector cable from the power card (Figure 41). • Screw the 3 spacers and unscrew the screw that fixes the motor cable (Figure 42). Figure 41 Figure 42 •...
  • Page 8: Om13 Module Setting And Configuration

    KEYSTONE OM13 - EPI-2 3-WIRES MODULE INSTALLATION AND MAINTENANCE INSTRUCTIONS • Connect the 3-pins connector cable of the OM13 module to the logic card (Figure 47). • Connect the 2-pins black connector from OM13 module to the 2-pins connector previously removed (Figure 48). •...
  • Page 9: Om13 Kit

    KEYSTONE OM13 - EPI-2 3-WIRES MODULE INSTALLATION AND MAINTENANCE INSTRUCTIONS 4. OM13 KIT Figures 51-54 allow to distinguish old version of EPI-2 from the new version (on the labels The OM13 kit consists of the following parts are underlined the digits of Product Number); (see Figure 49): furthermore, the logic boards with heatsink - OM13 modulating input/output module...
  • Page 10: Om13 Wiring Diagram

    KEYSTONE OM13 - EPI-2 3-WIRES MODULE INSTALLATION AND MAINTENANCE INSTRUCTIONS 5. OM13 WIRING DIAGRAM Blinker/ CLC1 CLC2 OPC2 OPC1 Monitor Local selector relay relay Output contacts (Note 2-4) MODULE 13 (3-WIRES) (Note 1) (Note 3) NOTES 1. L1 - L2 connection to open L2 - L3 connection to close Supply from 110 to 240 V AC / 1-ph L2 neutral...
  • Page 11 KEYSTONE OM13 - EPI-2 3-WIRES MODULE INSTALLATION AND MAINTENANCE INSTRUCTIONS Alternatively, to avoid induced voltage phenomena over floating command line, the following wiring diagram may be used. USE TO AVOID INDUCED VOLTAGE PHENOMENA Blinker/ CLC1 CLC2 OPC1 OPC2 Monitor Local selector relay relay Output contacts...
  • Page 12 Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user. Keystone is a mark owned by one of the companies in the Emerson Automation Solutions business unit of Emerson Electric Co. Emerson Automation Solutions, Emerson and the Emerson logo are trademarks and service marks of Emerson Electric Co.

This manual is also suitable for: