Installation - Emerson Fisher easy-Drive 200R Instruction Manual

Table of Contents

Advertisement

easy-Drive 200R
November 2023

Installation

WARNING
Always wear protective gloves, clothing, and eyewear when performing any installation operations to avoid personal
injury.
To avoid personal injury or property damage caused by bursting of pressure‐retaining parts or by uncontrolled process
fluid, be certain the service conditions do not exceed the limits shown on the valve nameplate and in table 1. Use
pressure‐relieving devices required by government or accepted industry codes and good engineering practices.
Check with your process or safety engineer for any additional measures that must be taken to protect against process
media.
If installing into an existing application, also refer to the WARNING at the beginning of the Maintenance section in this
instruction manual.
WARNING
For explosion­proof applications, ensure the actuator cover is properly bolted before applying power to the actuator.
Personal injury or property damage may result from fire or explosion if power is applied to the actuator with the cover
removed in a hazardous area.
For explosion‐proof applications, install rigid metal conduit and a conduit seal no more than 457 mm (18 in) from the
actuator. Personal injury or property damage may result from explosion if the seal is not installed.
Select wiring and/or cable glands that are rated for the environment of use (such as hazardous area, ingress protection, and
temperature). Failure to use properly rated wiring and/or cable glands can result in personal injury or property damage
from fire or explosion.
Wiring connections must be in accordance with local, regional, and national codes for any given hazardous area approval.
Failure to follow the local, regional, and national codes could result in personal injury or property damage from fire or
explosion.
WARNING
Avoid personal injury or property damage caused by possible actuator failure. The use of a rigidly‐mounted support on the
actuator casing may cause additional stress on the actuator leading to premature wear and/or failure of the actuator
components.
1. The easy-Drive 200R can be installed in any position. Install the valve per the manufactuer's guidelines and per any
applicable local, regional, and national piping codes.
2. For explosion-proof applications, install rigid metal conduit and seal no more than 457 mm (18 in) from the
actuator.
3. Plastic conduit ports provided by factory are to be removed prior to operation and replaced with an explosion-proof
port plug.
4
Instruction Manual
D104742X012

Advertisement

Table of Contents
loading