The table below indicates the various configuration options for fixed and traversing systems.
System Component
Sensor
Support Unit
Host Computer
Tile Holder
Rail Assembly
Specific Options
1-2
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Traversing System
All systems will contain a sensor that
may be:
Large Area View (LAV) with UV
Control (L01-1009-316)
LAV without UV Control (L01-1009-
317)
Small Area View (SAV) with UV
Control (L01-1009-318)
SAV without UV Control (L01-1009-
319)
All systems will contain a support unit
with motor control capabilities (L02-
1009-469)
All systems will contain a computer
that will operate the MultiSensor
Software or SheLyn software
All systems will contain a tile holder
that may be:
On the sensor (Automatic) (D01-1009-
461)
Manual Sample Holder (D02-1010-
216)
All systems will contain a traversing
rail assembly of 59.0-250.9 inches
(1500-6375 mm). A dual-position rail
with on-line and off-line positioning
only is also available (FUTURE).
The system may contain one or more of
the following options:
Positive-pressure air purge for sensor
window and automatic tile holder
(D02-1011-473)
Sensor vortex cooler (D02-1011-474
with heat shield, D02-1011-504
without heat shield)
Product backing strip (D02-1010-781)
Motion alarm (L01-1010-274)
Sheet Break/Seam Detector (L01-1009-
748)
Standard Edge Detectors (L02-1009-
533)
Diagonal Edge Detectors (L02-1009-
534)
All systems will contain a sensor that
may be:
Large Area View (LAV) with UV
Control (L01-1009-316)
LAV without UV Control (L01-1009-
317)
Small Area View (SAV) with UV
Control (L01-1009-318)
SAV without UV Control (L01-1009-
319)
All systems will contain a support unit
without motor control capabilities
(L02-1009-824)
All systems will contain a computer
that will operate the MultiSensor
Software or SheLyn software
All systems will contain an On-sensor
(Automatic) tile holder (D01-1009-
461) or Manual Sample Holder (D02-
1010-216)
All systems will contain a fixed
mounting assembly (D02-1009-812).
The system may contain one or more
of the following options:
Positive-pressure air purge for sensor
window and automatic tile holder
(D02-1011-473)
Sensor vortex cooler (D02-1011-474
with heat shield, D02-1011-504
without heat shield)
Product backing strip (D02-1010-781)
Standard Edge Detectors (L02-1009-
533)
Diagonal Edge Detectors (L02-1009-
534)
Four Movable Edge Detectors (D02-
1011-475)
Sheet Break/Seam Detector (L01-
Introduction
Fixed System
11/02