Hunter SVC Owner's Manual

Hunter SVC Owner's Manual

Smart valve controller
Hide thumbs Also See for SVC:

Advertisement

SVC
Smart Valve Controller
ENG
Owner's manual and programming instructions
Programador Autónomo de Pila
ESP
Instrucciones de instalacion y manual del usuario
Programmateur Autonome
FR
Guide de l'utilisateur et Instructions d'installation
Programmatore per Valvole Intelligente
IT
Guida per l'utente ed istruzioni per l'installazione
Das Intelligente Magnetventil-Steuergerät
DE
Hinweise zur installation und bedienungsanleitung
Programador de Válvulas Inteligente
PRT
Guia do utilizador e instruções de instalação

Advertisement

Table of Contents
loading

Summary of Contents for Hunter SVC

  • Page 1 Smart Valve Controller Owner’s manual and programming instructions Programador Autónomo de Pila Instrucciones de instalacion y manual del usuario Programmateur Autonome Guide de l’utilisateur et Instructions d’installation Programmatore per Valvole Intelligente Guida per l’utente ed istruzioni per l’installazione Das Intelligente Magnetventil-Steuergerät Hinweise zur installation und bedienungsanleitung Programador de Válvulas Inteligente Guia do utilizador e instruções de instalação...
  • Page 3: Table Of Contents

    Manual Watering ............11 Mounting the SVC ............6 To Suspend Manual Watering to All To Mount the SVC to a Valve ......... 6 Stations Operating ............12 Valve Box Mounting Method .......... 6 To Suspend Manual Watering to Individual Stake Mounting Method ..........
  • Page 4: Svc Features

    • Simple push button programming This section provides a brief overview of some of the com- ponents of the SVC. Each item will be discussed in further • Operates up to four valves detail later. However, this section can be helpful in getting •...
  • Page 5: Control Buttons

    Button – Selects programming function. Battery Status – Indicates the remaining life of the Button – Advances the selected flashing display to the battery in the SVC. next item. Manual On/Off – Icon indicates when manual Button – Navigates the selected flashing display back to watering is programmed.
  • Page 6: Connecting The Battery

    CONNECTING THE BATTERY To Install the Battery 1. Unscrew the rear half of the SVC body to gain access to The SVC uses a standard 9-volt alkaline battery (not the battery compartment. included) to operate the valve and program the controller.
  • Page 7: Attaching Solenoids

    Hunter DC solenoids (P/N 458200) can easily be installed responding station wire (red lead) from the SVC. The on all Hunter Plastic Valves. For the SVC-200 & SVC-400, station numbers are identified on the face of the SVC. solenoids must be ordered separately.
  • Page 8: Mounting The Svc

    3. Attach the large end of the valve mounting clip to the the valve box. middle of the SVC body. 3. Attach the SVC to the mounting clip and slide it on the 4. Snap the small end of the valve mounting clip to end of the mounting adapter.
  • Page 9: Stake Mounting Method

    4. Attached the SVC to the mounting clip and slide onto the display. the adapter. 1. Cut the yellow wire loop attached to the SVC at approxi- mately the middle of the loop. 2. Remove approximately ½" (13mm) of insulation from each wire.
  • Page 10: Programming

    The time and day have now been set. until the desired item is flashing. Setting Watering Start Times The SVC allows for up to 9 start times per day. Multiple start times permit morning, afternoon, and evening water- 1. Push the...
  • Page 11: Eliminating A Start Time

    Hold either button down for 1 second to change is displayed. times rapidly. 2. The display will show the last run time entered. 3. To add another start time to the station, press the 3. Use the button to change the station run time button.
  • Page 12: Selecting Interval Watering

    2. Wait 4 seconds and “Off” will appear on the display. multiple valves at the same time. Up to four stations can The SVC is now in the System Off mode and will remain operate at the same time. If more than one station has the...
  • Page 13: To Activate The Controller From The System Off Mode

    (up to 7). The SVC will steps 3 and 4. wait the number of days selected and then reactivate Note: While manual watering is occurring the display will automatic watering.
  • Page 14: To Suspend Manual Watering To All Stations Operating

    All stations will turn off. will appear as outlines 2. Press the button again and the current time and day will be displayed. The SVC will now water based upon the current program. To Suspend Manual Watering to Individual Stations Operating 1.
  • Page 15: Troubleshooting Guide

    Turn on main system supply. none is occurring. Faulty solenoid. Replace solenoid. Incompatible solenoid. Must use Hunter DC Latching Solenoid (P/N 458200) or other compatible DC latching solenoid. Automatic irrigation does not start Controller in System Off mode. Verify that controller is programmed for at start time.