Configuration and Operation
5.3.4.4

Periodic Event

The Periodic Event screen is used to specify an alarm to be triggered at a specified time interval.
Periodic Event
Select Off or On to activate this function. The default is Off.
Time Interval
In the Minimum interval text box, enter the number of seconds for the minimum interval between alarms.
The range is from 20 to 3600 seconds. The default is 60.
Triggered Action
The Administrator can specify various alarm actions to take when an alarm is triggered. See the
Triggered Actions
section for a detailed description of the actions. The following options are available:
·
Upload Image by FTP – Selecting this option enables you to assign an FTP site and configure
various parameters.
·
Upload Image by E-Mail – Selecting this option enables you to assign an e-mail address and
configure various parameters.
Click SAVE to save the network failure detection settings.
File Name
·
File Name – Enter a file name in the field, for example image.jpg. The uploaded image's file
name format is set in this section. Select one that meets your requirements.
·
Add date/time suffix (default setting)
File name: imageYYMMDD_HHNNSS_XX.jpg
Y: Year, M: Month, D: Day
H: Hour, N: Minute, S: Second
X: Sequence Number
·
Add sequence number suffix (no maximum value)
File name: imageXXXXXXX.jpg
X: Sequence Number
·
Add sequence number suffix (limited value)
File Name: imageXX.jpg
X: Sequence Number
The file name suffix ends at the number being set. For example, if the setting is up to "10," the file
name will start from 00, end at 10, and then start over again.
Quasar CP-6302 Range User Guide - Ver. 8 - January 31, 2021
Periodic Event Screen
This document does not contain any export-controlled information.