7.4. CAN Error Counter Register

Bit
Symbol Value
7:0
TEC
14:8
REC
15
RP
31:16
-
I-7565M-HS USB to CAN converter User Manual (version 1.0.0)
Copyright © 2018 ICP DAS Co., Ltd. All Rights Reserved. E-mail: service@icpdas.com
Transmit error counter
Current value of the transmit error counter (maximum value 255)
Receive error counter
Current value of the receive error counter (maximum value 127).
Receive error passive
0
The receive counter is below the error passive level.
The receive counter has reached the error passive level as defined
1
in the CAN2.0 specification.
-
Reserved
Description