*o_byMode
[out]
CAN message mode.
0: 2.0A, 11-bit CAN ID
1: 2.0B, 29-bit CAN ID
*o_dwID
[out]
CAN message ID parameter.
2.0A CAN message  0x000 ~ 0x7FF
2.0B CAN message  0x00000000 ~ 0x1FFFFFFF
Event message  0xEEEEEEE
*o_byRTR
[out]
CAN message RTR (Remote Transmission Request) parameter.
0: no RTR
1: RTR
*o_byDlen
[in]
CAN message data length parameter.
Valid range: 0 ~ 8.
*o_byData
[in/out] This point to an user defined eight bytes buffer for saving CAN message
data parameter
*o_dw_TimeStamp_s
[out]
The timestamp of the received/event message.
Unit: second.
*o_dw_TimeStamp_us
[out]
The timestamp of the received/event message.
Unit: micro second.
Return Value:
Return 0 means success, others means failure.
I-7565M-HS USB to CAN converter User Manual (version 1.0.0)
Copyright © 2018 ICP DAS Co., Ltd. All Rights Reserved. E-mail: service@icpdas.com