Step3: On the "CAN Port Enable" and "CAN1/CAN2 Baud Rate" location, user can set
the CAN Bus, and other prarameters. The detail functions of these parameters
are list below.
[CAN Port Enable]
"Port Enable" :
"Silent Mode" :
[CAN Baudrate]
"Baud Rate":
"Sample Point": Sample point of CAN baud rate bit timing.
Step4: Press the "Connect" buttom to start to use the above setting to send/receice
CAN messages.
I-7565M-HS USB to CAN converter User Manual (version 1.0.0)
Copyright © 2018 ICP DAS Co., Ltd. All Rights Reserved. E-mail: service@icpdas.com
Enable/Disable the CAN1/CAN2 port.
Set the CAN port into silent mode. When setting the CAN port into
silent mode, the CAN port will just receive CAN messages, no CAN
Ack command be sent to the CAN Bus.
CAN Bus baud rate in used. Valid range: 10 ~ 1000 kbps.