Emergency Measures For A Fault In The Potential Sensor - Canon iR5000 Service Handbook

Hide thumbs Also See for iR5000:
Table of Contents

Advertisement

8.6 Emergency Measures for a Fault in the Potential Sensor

If transfer separation fails because of a fault in the potential sensor, try using the follow-
ing service mode items to get around the problem; keep in mind, however, that this is no
more than a temporary measure used until the replacement of the potential sensor:
1. COPIER>OPTION>TEMPO>F-POT-SW
If the potential sensor has gone out of order and transfer separation faults occur as a re-
sult, enter '1'.
2. COPIER>OPTION>TEMPO>F-POT-D
The above service mode item must be set to '1':
0: if the user mainly uses originals with a low image ratio (text-oriented; default)
1: if the user mainly uses originals with a high image ratio (photo-oriented)
2: if retransfer (white spots around 50 mm along the leading edge)