3.3 Mounting the Drum Cleaning Blade

3.3.1 Removing the Cleaning Blade

1) Slide out the process unit from the ma-
chine. (See the Printer Manual : Chap.4
> 7.3 "Process Unit".)
2) Remove the primary charging assembly.
3) Disconnect the connector [1] of the AC
line of the drum heater.
4) Remove the four mounting screws [2],
and detach the cleaning blade assembly
[3].
5) Remove the E-ring [4] from under the
cleaning blade assembly, and detach the
pressure spring [5].
CHAPTER 2 STANDARDS AND ADJUSTMENTS
[3]
[2]
F02-203-09
[5]
[4]
F02-203-10
[1]
2-19