Adjusting The Position Of The - Canon iR5000 Service Handbook

Hide thumbs Also See for iR5000:
Table of Contents

Advertisement

CHAPTER 2 STANDARDS AND ADJUSTMENTS
When mounting the reader up-
per frame, be sure to go through
the following steps:
1) Fit the eight claws [1] of the reader
frame correctly into the cut-offs in the
reader upper frame.
2) Secure the positions [2] of the four left/
right claws using screws.
3) Fit the two screws [3] at the end.
2.2 Adjusting the Position of the Scanner Mirror Base
1) Set the pins of the mirror position tool
as indicated.
Initial FY9-3009-040 configuration
[A]
Initial FY9-3009-040 configuration
2-10
[C]
[B]
[A]
(for rear)
[C]
[B]
(for front)
[1]
Configuration used for the machine
[C]
[B]
Configuration used for the machine
F02-202-01
[2]
[1]
[3]
[1]
F02-201-06
[A]
[C]
[B]
(for rear)
[A]
(for front)
[1]