NetVanta 3000 Series Hardware Installation Guide
Instructions for Wall Mounting NetVanta 3205/NetVanta 3305
Step
1
Remove the mounting ears. Rotate them 90
flush with the bottom of the chassis, and reattach them to the chassis (see
2
Decide on a location for the unit. Keep in mind that the unit needs to be mounted at or below eye level so
that the LEDs are viewable. Important! Mount the chassis with LEDs facing to the side as shown in
Figure 41
(not facing up or down).
3
Prepare the mounting surface by attaching a board (typically plywood, 3/4-inch to 1-inch thick) to a wall
stud.
Important! Mounting to a stud ensures stability. Using sheetrock anchors may not provide sufficient long-
term stability.
4
Have an assistant hold the unit in position as you install two #6 to #10 (1-inch or greater in length) wood
screws through the unit's brackets and into the mounted board. See
5
Proceed to the steps given in

Figure 41. Repositioning the Mounting Bracket for Wall Mounting the NetVanta 3205/3305

61200860L1-34AA
Action
o
so that the portion of the bracket with the mounting holes is
Supplying Power to the Unit on page
Copyright © 2010 ADTRAN, Inc.
Unit Installation
Figure
41).
Figure
41.
83.
79