Netvanta T1/Ft1 Nim (P/N 1202862L1); Figure 27. Netvanta T1/Ft1 Nim - ADTRAN NetVanta 3458-PoE Hardware Installation Manual

Netvanta 3000 series routers
Hide thumbs Also See for NetVanta 3458-PoE:
Table of Contents

Advertisement

Option Modules

NetVanta T1/FT1 NIM (P/N 1202862L1)

The NetVanta T1/FT1 NIM (shown in
NetVanta 3000 Series. See
page 107
for the DBU connector pinouts. An optional DIM is required for dial backup applications.
Operating Modes
Frame Relay, multilink Frame Relay
PPP, MLPPP
HDLC
T1/FT1 Interface
Supported Standards: AT&T TR 62411,
AT&T TR 65016, ANSI T1.403,
Bellcore TR 194
Line Rate: 1.544 Mbps +75 bps
Line Code: AMI or B8ZS
Framing: D4 (SF) or ESF
FT1 Line Rate: DS0 channelized (multiples
of 64 kbps)
Input Signal: 0 to -36 dB (DS1)
Line Build Out: 0, -7.5, -15, -22.5 dB
(long), 0 to 655 ft. (short)
DS0 Assignment: Programmable
Connector: RJ-48C
Clock Source
Network
Internal
58
Figure
27) provides a T1 (full or fractional) WAN interface for the
Table A-7 on page 103
WAN-T1

Figure 27. NetVanta T1/FT1 NIM

Features and Specifications
Copyright © 2010 ADTRAN, Inc.
NetVanta 3000 Series Hardware Installation Guide
for the WAN-T1 connector pinouts, and
DBU
Diagnostics
Test Pattern Generation and Detection:
511, QRSS, all ones, all zeros
Network loopbacks (local and remote);
responds to both inband and FDL loop
codes
Alarm generation and detection
Network and user sets of performance data
(15 minutes and 24 hours)
Compliance
EMC - see Electromagnetic Compatibility
(EMC) Table on page 7.
ACTA/FCC Part 68
IC CS-03
UL/CUL 60950
Environmental
Operating Temperature: 0°C to 50°C
Storage Temperature: -20°C to 70°C
Relative Humidity: Up to 95 percent,
noncondensing
Physical
Dimensions: 2.75-inch W x 4.25-inch D
Table A-15 on
61200860L1-34AA