NetVanta 3000 Series Hardware Installation Guide
NetVanta Dual T1 NIM (P/N 1200872L1/1202872L1)
The NetVanta Dual T1 NIM (shown in
Series. The module provides up to 2.048 Mbps on each network interface. See
the pinouts. See
Table A-15 on page 107
dial backup applications.
Operating Modes
•
Frame Relay, multilink Frame Relay
•
PPP, MLPPP
•
HDLC
T1 Interface
•
Supported Standards: AT&T TR 62411,
AT&T TR 65016, ANSI T1.403,
Bellcore TR 194
•
Line Rate: 1.544 Mbps +75 bps
•
Line Code: AMI or B8ZS
•
Framing: D4 (SF) or ESF
•
FT1 Line Rate: DS0 channelized
(multiples of 64 kbps)
•
Input Signal: 0 to -36 dB (DS1)
•
Line Build Out: 0, -7.5, -15, -22.5 dB
(long), 0 to 655 ft. (short)
•
DS0 Assignment: Programmable
•
Connector: RJ-48C
Clock Source
•
Network
•
Internal
•
Through
The 1200872L1 Dual T1 module supports the analog modem (1200864L1), ISDN BRI
(1200865L1), and ISDN S/T (1200875L1) DIMs for dial backup applications. The
1202872L1 Dual T1 module supports only the analog modem (1200864L1) DIM for dial
backup applications.
61200860L1-34AA
Figure
30) provides two WAN T1 interfaces for the NetVanta 3000
for the DBU connector pinouts. An optional DIM is required for
WAN T1/1
WAN T1/2
Figure 30. NetVanta Dual T1 NIM
Features and Specifications
Copyright © 2010 ADTRAN, Inc.
Table A-7 on page 103
DBU
Diagnostics
•
Test Pattern Generation and Detection:
15
QRSS, 511, 2
- 1, 2
all zeros
•
Network loopbacks (local and remote);
responds to both inband and FDL loop
codes
•
Alarm generation detection
•
Network performance data (15 minutes
and 24 hours)
Compliance
•
EMC - see Electromagnetic
Compatibility (EMC) Table on page 7.
•
ACTA/FCC Part 68
•
IC CS-03
•
UL/CUL 60950
Environmental
•
Operating Temperature: 0°C to 50°C
•
Storage Temperature: -20°C to 70°C
•
Relative Humidity: Up to 95 percent,
noncondensing
Physical
•
Dimensions: 2.75-inch W x 4.25-inch D
Option Modules
for
20
- 1, all ones,
61