Figure 46. Installing Dims - ADTRAN NetVanta 3458-PoE Hardware Installation Manual

Netvanta 3000 series routers
Hide thumbs Also See for NetVanta 3458-PoE:
Table of Contents

Advertisement

Unit Installation
Step
1
Remove power from the unit.
2
If the NIM is already in the NetVanta chassis, remove all cables, release the pins at both edges of the NIM
front panel and slide the module out of the chassis.
3
Carefully align the P1 connector on the NIM with the J1 connector on the DIM. Using only fingertip
pressure so that neither circuit board bends or flexes, ensure that the connectors are firmly seated.
Secure the DIM to the NIM using the screws and standoff posts supplied. See
4
Slide the NIM with the DIM attached into the NetVanta chassis, continuing with the normal NIM installation
(refer to
Instructions for Installing the NIMs
Step
1
Remove power from the unit.
2
Slide the option module into the option slot until the module is firmly seated against the chassis.
3
Secure the pins at both edges of the module.
4
Connect the cables to the associated device(s).
5
Restore power to the unit.
88
NetVanta 3000 Series Hardware Installation Guide
Instructions for Installing the DIMs
Action
below).

Figure 46. Installing DIMs

Instructions for Installing the NIMs
Action
Copyright © 2010 ADTRAN, Inc.
Figure
46.
61200860L1-34AA

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents