Option Modules
NetVanta T1/FT1 NIM (P/N 1200862L1 or P/N 1202862L1)
The T1/FT1 NIM (shown in Figure 4) provides a T1 (full T1 or fractional T1) WAN interface for the
NetVanta 4305. Refer to Table A-4 on page 46 for the WAN-T1 connector pinout, and refer to Table A-9
on page 49 for the DBU connector pinout. An optional DIM is required for dial backup applications.
Features and Specifications
Operating Modes
•
T1/FT1 Frame Relay
•
T1/FT1 PPP
T1/FT1 Interface
•
Line Rate: 1.544 Mbps +/- 75 bps
•
Line Code: AMI or B8ZS
•
Framing: D4 (SF) or ESF
•
FT1 Line Rate: DS0 Channelized
(multiples of 56/64 kbps)
•
Input Signal: 0 to -36 dB (DS-1)
•
Line Build-Out: 0, -7.5, -15, -22.5 dB
•
Connector: RJ-48C
•
DS0 Assignment: Programmable
Clock Source
•
Network
•
Internal
Diagnostics
•
Test pattern generation and detection: 511,
QRSS (2nd Gen only)
•
Network loopbacks (local and remote);
responds to both INBAND and FDL loop
codes
•
Alarm generation and detection
•
Network and user sets of performance data
(15 minutes and 24 hours)
28
WAN-T1
Figure 4. NetVanta T1/FT1 NIM
Relevant Requirements/Standards
•
•
•
•
•
•
•
Environmental
•
•
•
Physical
•
© 2004 ADTRAN, Inc.
NetVanta 4305 Hardware Installation Guide
DBU
EMC - see Electromagnetic Compatibility
(EMC) Table on page 6.
ACTA/FCC Part 68
Industry Canada CS03
UL and CUL
T1 Interface: Pub 62411
ESF Format Interface: TR. 194
ESF Performance Monitoring: TR. 54016
and T1.403
Operating Temperature: 0 to 50
Storage Temperature: -40 to 85
Relative Humidity: Up to 95%
noncondensing
Dimensions: 4.25" x 2.75"
o
C
o
C
61200890L1-34B