4.1.4 Group 3 Analog Input/Output Parameters

Pr.
Explanation
Analog Input 1 (AUI1)
03-00
Analog Input 2 (ACI)
03-01
Analog Input 3 (AUI2)
03-02
Analog Input Bias 1 (AUI1)
03-03
Analog Input Bias 2 (ACI)
03-04
Analog Input Bias 3 (AUI2)
03-05
Positive/negative Bias Mode
03-06
(AUI1)
Positive/negative Bias Mode
03-07
(ACI) (can be set to 0 or 1
only)
Positive/negative Bias Mode
03-08
(AUI2)
Analog Input Gain 1 (AUI1)
03-09
Analog Input Gain 2 (ACI )
03-10
Analog Input Gain 3 (AUI2)
03-11
Analog Input Delay Time
03-12
(AUI1)
Analog Input Delay Time
03-13
(ACI)
Analog Input Delay Time
03-14
(AUI2)
Loss of the ACI Signal
03-15
Reserved
03-16
Analog Output Selection 1
03-17
Analog Output Gain 1
03-18
Call 1(800)985-6929 for Sales
deltaacdrives.com
Settings
0: No function
1: Frequency command (torque limit under TQR control mode)
2: Torque command (torque limit under speed mode)
3: Preload Input
4-5: Reserved
6: P.T.C. thermistor input value
7: Positive torque limit
8: Negative torque limit
9: Regenerative torque limit
10: Positive/negative torque limit
-100.0~100.0%
-100.0~100.0%
-100.0~100.0%
0: Zero bias
1: Serve bias as the center, lower than bias=bias
2: Serve bias as the center, greater than bias=bias
3: The absolute value of the bias voltage while serving as the
center (single polar)
4: Serve bias as the center (single polar)
-500.0~500.0%
-500.0~500.0%
-500.0~500.0%
0.00~2.00 sec
0.00~2.00 sec
0.00~2.00 sec
0: Disable
1: Continue operation at the last frequency
2: Decelerate to 0Hz
3: Stop immediately and display E.F.
0: Output frequency (Hz)
1: Frequency command (Hz)
2: Motor speed (RPM)
3: Output current (rms)
4: Output voltage
5: DC Bus Voltage
6: Power factor
7: Power
8: Output torque
9: AUI1
10: ACI
11: AUI2
12: q-axis current
13: q-axis feedback value
14: d-axis current
15: d-axis feedback value
16: q-axis voltage
17: d-axis voltage
18: Torque command
19-20: Reserved
0~200.0%
4-7
deltaacdrives.com
sales@deltaacdrives.com
Chapter 4 Parameters|
Factory
Setting
1
0
0
0.0
0.0
0.0
0
0
0
100.0
100.0
100.0
0.01
0.01
0.01
0
0
100.0
sales@deltaacdrives.com
VFD-VL
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○