General Information; Emc Notice - Barco Demetra User Manual

Hide thumbs Also See for Demetra:
Table of Contents

Advertisement

Important information
La bande 5 150-5 250 MHz est réservés uniquement pour une utilisation à l'intérieur afin de réduire les
risques de brouillage préjudiciable aux systèmes de satellites mobiles utilisant les mêmes canaux.
For the frequency 5600-5650 MHz, no operation is permitted.
Pour la fréquence 5600-5650 MHz, aucune opération est autorisée.
Radiation exposure statement
These requirements set a SAR limit of 1.6 W/kg averaged over one gram of tissue. The highest SAR value
reported under this standard during product certification for use when properly worn on the body is 1.148 W/
kg.
Ces exigences établissent une limite SAR de 1,6 W/kg en moyenne sur un gramme de tissu. La valeur SAR la
plus élevée déclarée selon cette norme lors de la certification du produit à utiliser lorsqu'il est correctement
porté sur le corps est de 1.148 W/kg.

8.3.4 General information

Manufacturing country
The manufacturing country of the product is indicated on the product label ("Made in ...").
Importers contact information
To find your local importer, contact one of Barco's regional offices via the contact information provided on our
website (www.barco.com).

8.4 EMC notice

General information
This device is for use in professional healthcare facility environments only.
With the installation of the device, use only the delivered external cables and power supply or a spare part
provided by the legal manufacturer. Using another can result in a decrease of the immunity level of the device.
WARNING: Use of this equipment adjacent to or stacked with other equipment should be avoided
because it could result in improper operation. If such use is necessary, this equipment and the other
equipment should be observed to verify that they are operating normally.
WARNING: Use of accessories, transducers and cables other than those specified or provided by
the manufacturer of this equipment could result in increased electromagnetic emissions or
decreased electromagnetic immunity of this equipment and result in improper operation.
WARNING: Portable RF communications equipment (including peripherals such as antenna cables
and external antennas) should be used no closer than 30 cm (12 inches) to any part of the Demetra
solution, including cables specified by the manufacturer. Otherwise, degradation of the performance
of this equipment could result.
Electromagnetic emissions
The Demetra solution is intended for use in the electromagnetic environment specified below. The customer or
the user of the Demetra solution should assure that it is used in such an environment.
Emissions test
RF emissions
CISPR 11
RF emissions
CISPR 11
48
K5902200 /02AC
Compliance
Group 1
Class B
Barco Demetra
Electromagnetic environment –
Guidance
The Demetra solution uses RF
energy only for its internal function.
Therefore, its RF emissions are
very low and are not likely to cause
any interference in nearby
electronic equipment.
The Demetra solution is suitable for
use in all establishments, including

Advertisement

Table of Contents
loading

Table of Contents