Summary of Contents for Barco Eonis MDRC-2122 BL

  • Page 1 Eonis User Guide 22-inch clinical display MDRC-2122 BL - MDRC-2122 TS MDRC-2122 WH - MDRC-2122 WP MDRC-2122 WT K5903049/06 11/10/2016...
  • Page 2 Barco NV President Kennedypark 35, 8500 Kortrijk, Belgium Phone: +32 56.23.32.11 Fax: +32 56.26.22.62 Support: www.barco.com/en/support Visit us at the web: www.barco.com Printed in Belgium...
  • Page 3: Table Of Contents

    Table of contents TABLE OF CONTENTS 1. Welcome! ..................3 About the product .................... . 3 Symbols .
  • Page 4 Table of contents K5903049 EONIS 11/10/2016...
  • Page 5: Welcome

    The multi- ple mounting options and connections further add to the smart design typical of Barco’s Eonis display. Most unique, however, is the excellent cleanability of the WP version of the display thanks to the tough- ened and scratch-proof glass.
  • Page 6: Symbols

    1. Welcome! Symbols Symbols in this document The following symbols are used in this document: Caution: describes hazards that could damage the product. Warning: describes hazards or dangers that might result in personal injury or death. Note: gives extra information about the described subject Tip: gives extra advice about the described subject What’s in the box Overview...
  • Page 7: Parts, Controls And Connectors

    2. Parts, controls and connectors 2. PARTS, CONTROLS AND CONNECTORS Front view Overview Image 2-1 1. Front sensor 2. USB downstream connector 3. Left / Decrease key 4. Right / Increase key 5. Menu / Enter key 6. Standby key 7.
  • Page 8: Rear View

    2. Parts, controls and connectors Rear view Overview 10 11 Image 2-2 1. Connector compartment cover 2. Kensington security slots 3. Opening for cable routing strap 4. Height mechanism lock screw 5. VGA input 6. HDMI audio line out 7. USB downstream connector 8.
  • Page 9: Display Installation

    3. Display installation 3. DISPLAY INSTALLATION Unlocking the height mechanism To unlock the height mechanism In the factory, the height mechanism in the stand of your Eonis display is locked to prevent damage dur- ing transportation. You’ll first have to unlock this mechanism before you can adjust your display height position.
  • Page 10: Removing The Cover

    3. Display installation Image 3-2 Do not try to pivot your display when attached to the stand. Trying to do so AUTION could cause serious damage to your display and its stand. Removing the cover To remove the connector compartment cover The connector compartment cover should be removed to get access to the connectors.
  • Page 11: Re-Attaching The Cover

    3. Display installation 4. Connect the supplied external DC ( ) power supply to the +12 VDC power input of your display. 5. Plug the other end of the external DC ( ) power supply into a grounded power outlet by means of the proper power cord delivered with your display.
  • Page 12: Kensington Security Slots

    3. Display installation 3. Wrap and fix the cable routing strap around all cables. Image 3-6 Kensington security slots To make use of the Kensington security slots Your Eonis display has 2 Kensington slots available which allow you to secure the display to a desk or any other fixed object.
  • Page 13 3. Display installation Image 3-8 Use an arm that can support a weight of at least 12 kg (26.50 lbs). Failure to AUTION do so could make the panel fall, causing serious injury to a child or adult, and serious damage to the equipment.
  • Page 14 3. Display installation K5903049 EONIS 11/10/2016...
  • Page 15: Daily Operation

    To ensure optimal product quality, Barco applies strict selection criteria for its LCD panels. To learn more about LCD technology and missing pixels, consult the dedicated white papers available at www.barco.com/healthcare.
  • Page 16: On/Off Switching

    4. Daily operation On/Off switching To switch your display on or off 1. Shortly press the Standby ( ) key. Bringing up the OSD menus About the OSD menu The OSD menu allows you to configure different settings to make your Eonis display fit your needs within your working environment.
  • Page 17: Advanced Operation

    5. Advanced operation 5. ADVANCED OPERATION Video input source selection About video input source selection By default, your Eonis display automatically detects and shows the connected video input source. How- ever, when for instance more then one video input source is connected, it may be needed to manually select the input source to be displayed.
  • Page 18: Ambient Light Reading Room Selection

    DICOM: DICOM (Digital Imaging and Communications in Medicine) is an international standard that was developed to improve the quality and communication of digital images in radiology. In short, the DICOM gamma function results in more visible grayscales in the images. Barco recommends selecting the DICOM gamma function for most medical viewing applications.
  • Page 19: Analog Video Settings

    5. Advanced operation • Native: The native, unmodified color temperature of the LCD panel. • 6500K (sRGB): Corresponds to a color temperature of 6500 Kelvin (D65). • QAWeb: This white point setting will be automatically selected when white point is defined by MediCal QAWeb.
  • Page 20: Power Status Led

    5. Advanced operation 2. Navigate to the Adjustments > Settings menu. 3. Enter the Language submenu. 4. Select one of the available languages. Power status LED About the power status LED By default, the power status LED has the following behavior: •...
  • Page 21: Self Calibration Frequency

    5. Advanced operation 5.10 Self calibration frequency About self calibration The front sensor of your Eonis display measures the output luminance of your screen and allows the display to automatically stabilize its luminance for maximum image quality over the displays’ lifetime. This self calibration is done at an adjustable, predefined frequency: •...
  • Page 22 5. Advanced operation K5903049 EONIS 11/10/2016...
  • Page 23: Maintenance

    The Eonis display does not require any scheduled maintenance or calibration activities. We recommend to use QAWeb with the Barco default tests and frequencies to calibrate and maintain the display or return the display to a Barco approved maintenance organization. In any case of doubts, contact the Barco Healthcare Division.
  • Page 24 6. Maintenance K5903049 EONIS 11/10/2016...
  • Page 25: Important Information

    7. Important information 7. IMPORTANT INFORMATION Safety information General recommendations Read the safety and operating instructions before operating the device. Retain safety and operating instructions for future reference. Adhere to all warnings on the device and in the operating instructions manual. Follow all instructions for operation and use.
  • Page 26 7. Important information To fully disengage the power to the device, please disconnect the power cord from the AC inlet. Power cords: • Do not overload wall outlets and extension cords as this may result in fire or electric shock. •...
  • Page 27: Environmental Information

    Sweden: "Apparaten skall anslutas till jordat uttag" Essential performance Barco states that the Eonis display is only used for reviewing medical digital images. These reviews are done in rooms where the equipment is unlikely to be in contact with patients. With this information, if the display fails, the patient is not in direct danger for harm.
  • Page 28 Mainland, marked with the Environmental Friendly Use Period (EFUP) logo. The number inside the EFUP logo that Barco uses (please refer to the photo) is based on the “General guidelines of environ- ment-friendly use period of electronic information products” of Chinese Mainland.
  • Page 29: Regulatory Compliance Information

    7. Important information Regulatory compliance information Indications for use This display is an AMLCD display designed for viewing medical X-ray images. This unit should not be used near patients (where patients are likely to be in unconscious condition) and should be kept outside of 1.83 m perimeter and 2.29 m vertical.
  • Page 30 7. Important information Emissions test Electromagnetic environment – Compliance Guidance RF emissions Class B The Eonis display is suitable for use in all establishments, CISPR 11 including domestic establishments Harmonic emissions Class D and those directly connected to IEC 61000-3-2 the public low-voltage power Voltage fluctuations/ flicker Complies...
  • Page 31 7. Important information Immunity test Electromagnetic IEC 60601 Compliance level environment – Test levels guidance Voltage dips, short Mains power quality < 5% U (> 95% dip in < 5% U (> 95% dip in interruptions and voltage ) for 0.5 cycle ) for 0.5 cycle should by that of a typical variations on power...
  • Page 32 7. Important information Immunity test Electromagnetic IEC 60601 Compliance level environment – Test levels guidance Not applicable Power frequency (50/60 3 A/m Power frequency Hz) magnetic field magnetic fields should be at levels characteristic IEC 61000-4-8 of a typical location in a typical commercial or hospital environment.
  • Page 33: Explanation Of Symbols

    7. Important information At 80 MHz and 800 MHz, the higher frequency range applies. These guidelines may not apply in all situations. Electromagnetic propagation is af- fected by absorption and reflection from structures, objects and people. Recommended separation distance The Eonis display is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled.
  • Page 34 7. Important information Indicates compliance with Part 15 of the FCC rules (Class A or Class B) Indicates the device is approved according to the UL regulations Indicates the device is approved according to the UL regulations for Canada and US Indicates the device is approved according to the UL regulations for Canada and US Indicates the device is approved according to the UL Demko regulations...
  • Page 35 7. Important information Indicates the temperature limitations for the device to safely operate within specs Indicates the device serial number Indicates the device part number or catalogue number Warning: dangerous voltage Caution Consult the operating instructions Indicates this device must not be thrown in the trash but must be recycled, according to the European WEEE (Waste Electrical and Electronic Equipment) directive Indicates Direct Current (DC)
  • Page 36: Legal Disclaimer

    Barco software products are the property of Barco. They are distributed under copyright by Barco NV or Barco Inc., for use only under the specific terms of a software license agreement between Barco NV or Barco Inc. and the licensee. No other use, duplication, or disclosure of a Barco software product, in any form, is authorized.
  • Page 37: Technical Specifications

    7. Important information Technical specifications MDRC-2122 BL and MDRC-2122 WH Screen technology TFT Color LCD IPS Active screen size (diagonal) 542 mm (21.5”) Active screen size (H x V) 267,3 mm x 475,2 mm (10.52” x 18.71”) Aspect ratio (H:V) 16:9 Resolution 2MP (1920 x 1080)
  • Page 38 7. Important information Certifications CE (MDD 93/42/EEC class I product), CE-2014/30/EU, IEC 60950-1:2005 + A1:2009 (2ND EDITION), IEC 60601-1 2ND ED:1988 + A1:1991 + A2:1995, IEC 60601-1:2005 + A1:2012, ANSI/AAMI ES 60601-1:2005 + C1:2009 + A1:2012, CAN/CSAC22.2 No. 60601-1-08:2008, DEMKO - EN 60601- 1:2006, EN 60601-1-2:2007, EN 60601-1:2006+A11:2011, KC, VCCI, FCC class B, ICES-001 Level B, FDA Class I device, RoHS MDRC-2122 BL only: CCC - GB9254-2008 + GB4943-2001 +...
  • Page 39 7. Important information Video input signals VGA, DisplayPort, HDMI USB ports 1 upstream, 2 downstream USB standard Power requirements (nominal) 100-240 V Power consumption (nominal) 40 W (<0,5 W in stand-by) Power save mode Power management DPMS Dot clock 165 MHz OSD languages English, French, German, Spanish, Italian, Dutch Dimensions with stand (W x H...
  • Page 40 7. Important information 7500 m Storage altitude Operating pressure 70 kPa - 106 kPa Storage pressure 50 kPa - 106 kPa MDRC-2122 TS and MDRC-2112 WT Screen technology TFT Color LCD IPS Touch screen PCAP multitouch 10 points Active screen size (diagonal) 542 mm (21.5”) Active screen size (H x V) 267,3 mm x 475,2 mm (10.52”...
  • Page 41 7. Important information Pivot Mounting standard VESA (75 mm) Screen protection Protective, non-reflective glass cover Certifications CE (MDD 93/42/EEC class I product), CE-2014/30/EU, IEC 60950-1:2005 + A1:2009 (2ND EDITION), IEC 60601-1 2ND ED:1988 + A1:1991 + A2:1995, IEC 60601-1:2005 + A1:2012, ANSI/AAMI ES 60601-1:2005 + C1:2009 + A1:2012, CAN/CSAC22.2 No.