Cr200(X) Example Program - Campbell 05103 Product Manual

Wind monitor series
Hide thumbs Also See for 05103:
Table of Contents

Advertisement

B.3 CR200(X) Example Program
CRBasic Example B-3. CR200(X) Example Program
'CR200/CR200X Series
'Declare Variables and Units
Public
BattV
Public
WS_ms
Public
WindDir
Units
BattV=Volts
Units
WS_ms=meters/second
Units
WindDir=degrees
'Define Data Tables
DataTable(Hour,True,-1)
DataInterval(0,60,Min)
WindVector(WS_ms,WindDir,False,0,0)
FieldNames("WS_ms_S_WVT,WindDir_D1_WVT,WindDir_SD1_WVT")
EndTable
'Main Program
BeginProg
'Main Scan
Scan(5,Sec)
'Default Data Logger Battery Voltage measurement 'BattV'
Battery(BattV)
'05103 Wind Speed & Direction Sensor measurements 'WS_ms' and 'WindDir'
'WS_ms
PulseCount(WS_ms,P_LL,1,1,0.098,0)
'WindDir
ExDelSE(WindDir,1,1,1,mV2500,20000,0.142,0)
If
WindDir>=360 Or WindDir<0
'Call Data Tables and Store Data
CallTable
NextScan
EndProg
Then
Hour
Appendix B. Example Programs
WindDir=0
B-3

Advertisement