Download Print this page

Campbell 05103 Instruction Manual

Wind monitor
Hide thumbs Also See for 05103:

Advertisement

05103, 05106, and 05305
R.M. Young Wind Monitors
Revision: 2/04
C o p y r i g h t
( c )
1 9 8 4 - 2 0 0 4
C a m p b e l l
S c i e n t i f i c ,
I n c .

Advertisement

loading
Need help?

Need help?

Do you have a question about the 05103 and is the answer not in the manual?

Questions and answers

Summary of Contents for Campbell 05103

  • Page 1 05103, 05106, and 05305 R.M. Young Wind Monitors Revision: 2/04 C o p y r i g h t ( c ) 1 9 8 4 - 2 0 0 4 C a m p b e l l S c i e n t i f i c ,...
  • Page 2 Warranty and Assistance The 05103, 05106, AND 05305 R.M. YOUNG WIND MONITORS are warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in materials and workmanship under normal use and service for twelve (12) months from date of shipment unless specified otherwise. Batteries have no warranty.
  • Page 3: Table Of Contents

    5. Maintenance and Repairs...........4 6. References ..............5 Figures 2-1. Wind Monitor Mounted to a Vertical Pipe ..........1 2-2. Wind Monitor Mounted to Campbell Scientific’s 019 Crossarm Mount.2 3-1. Wind Monitor Connections to Campbell Scientific Dataloggers.....3 Tables 4-1. Wind Speed Multiplier ................3...
  • Page 4 This is a blank page.
  • Page 5: Introduction

    1. Introduction These notes provide information for interfacing Campbell Scientific’s dataloggers to the R.M. Young 05103 Wind Monitor, 05106 Wind Monitor Marine, and 05305 Wind Monitor AQ. The 05305 Wind Monitor AQ is a high performance version of the Wind Monitor that is designed specifically for air quality measurements.
  • Page 6: Sensor To Datalogger Wiring

    05103, 05106, and 05305 R.M. Young Wind Monitors FIGURE 2-2. Wind Monitor Mounted to Campbell Scientific's 019 Crossarm Mount 3. Sensor to Datalogger Wiring Wire the Wind Monitor leads to the datalogger (see Figure 3-1). ® The black outer jacket of the cable is Santoprene rubber.
  • Page 7: Programming

    4. Programming This section is for users who write their own datalogger programs. A datalogger program to measure this sensor can be created using Campbell Scientific’s ShortCut Program Builder software. You do not need to read this section to use ShortCut.
  • Page 8: Wind Direction Instruction Code

    Table 4-1 is divided by the execution interval in seconds to obtain the multiplier used with code 11. For example, with a 10-second execution interval, the multiplier for meters/second with the 05103 would be 0.0980/10 = 0.0098. The offset remains zero. 4.2 Wind Direction Instruction Code The wind direction sensor is a potentiometer that is measured as a “half...
  • Page 9: References

    05103, 05106, and 05305 R.M. Young Wind Monitors 6. References Gill, G.C., 1973: The Helicoid Anemometer Atmosphere, II, 145-155. Baynton, H.W., 1976: Errors in Wind Run Estimates from Rotational Anemometers Bul. Am. Met. Soc., vol. 57, No. 9, 1127-1130.
  • Page 10 05103, 05106, and 05305 R.M. Young Wind Monitors This is a blank page.
  • Page 11 This is a blank page.
  • Page 12 Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com info@campbellsci.com Campbell Scientific Africa Pty. Ltd. (CSAf) PO Box 2450 Somerset West 7129 SOUTH AFRICA www.csafrica.co.za sales@csafrica.co.za Campbell Scientific Australia Pty. Ltd. (CSA)

This manual is also suitable for: