7.3

Wiring

7.4

Programming

NOTE
Connections to Campbell Scientific data loggers are given in TABLE 7-1.
When Short Cut software is used to create the data logger program, the sensor
is wired to the terminals shown in the wiring diagram created by Short Cut.
TABLE 7-1. Wire Color, Wire Function, and
Wire
Wire
Color
Function
Red
WS Signal
WS Signal
Black
Reference
Green
WD Signal
WD Voltage
Blue
Excitation
WD Signal
White
Reference
Clear
Shield
1
U terminals are automatically configured by the measurement instruction.
Short Cut is the best source for up-to-date data logger programming code.
If your data acquisition requirements are simple and you are connecting the
sensor to a pulse terminal, you can probably create and maintain a data logger
program exclusively by using Short Cut. If your data acquisition needs are
more complex, the files that Short Cut creates are a great source for
programming code to start a new program or add to an existing custom
program.
Short Cut cannot edit programs after they are imported and edited
in CRBasic Editor.
A Short Cut tutorial is available in Section 4, QuickStart
import Short Cut code into CRBasic Editor to create or add to a customized
program, follow the procedure in Appendix A, Importing Short Cut Code Into
CRBasic Editor
. Programming basics for CRBasic data loggers are
(p. A-1)
provided in the following sections. Complete program examples for select
CRBasic data loggers can be found in Appendix B, Example Programs
Programming basics and programming examples for Edlog data loggers are
provided at
www.campbellsci.com\old-manuals.
Data Logger Connection
Data Logger Connection Terminal
U configured for pulse input
or P_LL (pulse, low-level AC)
U configured for single-ended analog input
SE (single-ended, analog input)
U configured for voltage excitation
VX (voltage excitation)
⏚ (analog ground)
⏚ (analog ground)
Wind Monitor Series
, P (pulse input),
1
1
,
, EX, or
1
. If you wish to
(p. 2)
.
(p. B-1)
11