Technical data

DSWb with one pump:
Type
Pumps
Nominal width of pipework
Nominal width of flushing connector
Nominal width of relief valve return
line
Dimensions (WxHxD) in mm
Pulsation damper
Volume of vacuum cylinder
Max. capacity
Max. operating pressure (25 °C)
Max. operating pressure (40 °C)
Type
Pumps
Nominal width of pipework
Nominal width of flushing connector
Nominal width of relief valve return line
Dimensions (WxHxD) in mm
Pulsation damper
Volume of vacuum cylinder
Max. capacity
Max. operating pressure (25 °C)
Max. operating pressure (40 °C)
You will find the technical data for the metering pump and the other units
(back pressure valve, multifunctional valve, pulsation damper etc.) in the
product-specific operating instructions.
Storage and transport temperature of the metering system; 0 ... 50 °C
Maximum air humidity: 95% relative humidity
Maximum permissible operating pressure:
10 bar at 25 °C (feed chemical)
n
6 bar at 40 °C (feed chemical)
n
Electrical data for leakage sensor:
Switching voltage: 48 V
n
Switching current: 0.5 A
n
Switching power: 10 W / 12 VA
n
Type of contact: N/C
n
SP10
Beta 4/5b, DLTa, GMXa
DN 10
DN 10
DN 10
800x1200x300
0.09 l
0.5 l
75 l/h
10 bar
6 bar
S220
Sigma/ 2
DN 20
DN 15
DN 15
0.36 l
2.5 l
350 l/h
10 bar
6 bar
S110
S115
Sigma/ 1
Sigma/ 1
DN 10
DN 15
DN 10
DN 10
DN 10
DN 10
1000x1400x45
1200x1600x450
0
0.36 l
0.36 l
0.5 l
1 l
65 l/h
120 l/h
10 bar
10 bar
6 bar
6 bar
S325
S332
Sigma/ 3
Sigma/ 3
DN 25
DN 32
DN 20
DN 25
DN 20
DN 25
1200x1600x450
0.36 l
0.95 l
PDS 750 G
2.5 l
5.0 l
365 l/h
1040 l/h
10 bar
8* / 10 bar
* with pulsation damper
option
6 bar
6 bar
Technical data
S215
Sigma/ 2
DN 15
DN 10
DN 10
0.36 l
1 l
135 l/h
10 bar
6 bar