S-Register: S7
Function:
Unit:
Range:
Default:
Description:Sets the Abort Timer delay time, which is the length of time the TA waits for a
S-Register: S8
Function:
Unit:
Range:
Default:
Description:S8 sets the length of the pause caused by a comma inserted in a dialing
S-Register: S10
Function:
Unit:
Range:
Default:
Description:Sets the time after a carrier signal is lost before the TA disconnects. (The
S-Register: S25
Function:
Unit:
Range:
Default:
Description:Sets the time that DTR must remain low before TA disconnects. The S25 unit
MTA128ST-USB
Chapter 4 - AT Commands, S-Registers and Result Codes
Wait for Connection (Abort Timer)
1 second
0–255
45
connection after dialing. If no connection is established during the specified
time, the TA ends the call.
Pause Time for Comma
1 second
n=0-255
2 (2 seconds)
command. The default setting is 2 seconds, where each unit is one second.
S8 may be set for up to 255 seconds.
DCD Drop Time
50 ms
0–254, 255
20
&C2 command must be in effect.) Default setting is one second. Maximum
delay is 25.4 seconds (S10=254). Set S10 to 255 to cause the TA not to
disconnect with loss of carrier.
DTR Drop Time
100 ms
0, 1–255
5
value for 0 is 50 ms. For values from 1 through 255, the unit value is 100 ms.