MultiModemISDN User Guide
S-register: S75
Function:
Unit:
Range:
Default:
Description:S75 allows the maximum V.110 buffer size to be customized. An adjustable
S-register: S76
Function:
Unit:
Range:
Default:
Description:If S77=1, then the network rate of the V.110 connection will match that of
S-register: S77
Function:
Unit:
Range:
Default:
Description:The Network Rate for V.110 will be determined by S76 ($MB). If S77=1,
56
complete. The PPP Magic-Number Block contains 5 Magic-Numbers in this
implementation and is the default type. The Public Switched Network
Directory Number option uses Data Directory Number 1 as the Endpoint
Discriminator (if it is blank, then Endpoint Discriminator is blank). The
Locally Assigned Address (S73=1), IP Address (S73=2), and IEEE 802.1
Globally Assigned MAC Address (S73=3) options currently generate a
random value similar to the PPP Magic-Number Block, except that the length
of the Endpoint Discriminator follows according to the specifications for the
respective type. Refer to RFC 1990 for more information about the MultiLink
Endpoint Discriminator option and its types.
Maximum V.110 Buffer Size
1 byte
n=0 (256 bytes),
n=64-255
0 (256 bytes)
packet size can provide higher compatibility with devices that cannot handle
a large delay. Reducing the V.110 buffer size reduces delay.
V.110 Network Rate
decimal ASCII code
n=1—-—600 bps,
n=2——1200 bps,
n=3——2400 bps,
n=4——4800 bps,
n=5——9600 bps,
n=6—19200 bps,
n=7—38400 bps,
7 (38400 bps)
S76 ($MB). If a V.110 call is received and S77=1, then the incoming V.110
network rate must match S76 ($MB) or the connection will fail. If S77=2 and
a V.110 call is originated, then the network rate will match that of S76 ($MB).
If S77=2 and a V.110 call is received, then the setting of S76 ($MB) will have
no effect on the network rate of that call (see S77 for a description for this
case). The value of S76 will change if $MB is changed and the value of $MB
will change if S76 is changed.
V.110 Network Rate Control
decimal ASCII code
n=1—use $MB (S76),
n=2—use $MB (S76) or Auto Sync on Answer
2 (use $MB(S76) or Auto Sync on Answer)
then the network rate will be set to that of S76 ($MB) and if the network does
not match that of the peer device, then the connection will fail. Properties of
S77=1 apply to both received and originated calls. If the TA will be
answering a V.110 call, then it can be set to auto-synchronize (S77=2) on the
incoming V.110 network rate.